9-10
IQ plus 800/810 Installation Manual
ID Numbers is a feature that supports an ID number not associated with the
truck program or weight storage. To enter an ID the user enters a number up
to seven digits long and presses the NEW ID key. The number is saved and
can be printed on any formattable print ticket. The ID entered will remain
unchanged until the user enters a new ID number. This ID number cannot
be disabled, but if it is not formatted on any of the print tickets it will be
ignored. See the example below.
Example:
The user enters "1234567" and presses the NEW ID key and then the
PRINT key. The print ticket can look like this:
SCALE #1
ID # 1234567
GROSS 3780 LB
9/1/93 8:30 PM
You can print weight data from any active channel. Time and date will
be printed independently or together. ID number and consecutive
number can be added to the ticket (see Section 3, Configuration, for
more information on ID numbers and consecutive numbering). All of
the accumulators can be printed on the ticket. See the example below.
Example:
GFMT=SCALE#<S><NL><G>GROSS<NL>ID#<ID><NL2><TD><NL>
This string will produce the following ticket:
SCALE# 1
xxxxxxxx LB GROSS
ID# aaaaaaa
11:11 01/01/94
where xxxxxxxx is the current gross weight and aaaaaaa is the current
ID number.