Standard features

Table 1-2.
All standard models feature...
• 110 or 220 VAC operation
• 10-key numerical keyboard
• LED indicators
• Single-scale load cell input (expandable to four scales)
• Load cell excitation voltage to support 32 (700-Ω) or 16 (350-Ω) load cells
• Front panel configuration or downloadable setup from personal
computer or ASCII terminal
• Front panel calibration with internal memory to store calibration constants
• Field-replacement of complete units or components without recalibrating
• Three digital inputs (TTL or switch closure) configurable to duplicate
keyboard functions or facilitate batching operations
• 20 fully programmable setpoints (continuous or batch steps)
• Four digital setpoint outputs (16 with setpoint output expander module)
• One Electronic Data Processing (EDP) serial port configurable as duplex
RS-232 or 20mA current loop with optional RS-485
• One serial printer port configurable for simplex RS-232 and/or simulta-
neous 20mA current loop
• Accumulate function
• Formattable custom printing, including time, date, and custom headers
• Both analog filtering and exclusive digital RattleTrap
• Truck In/Out program with 200 ID's and choice of 6 operating modes

Optional features

Table 1-3.
Optional features include...
• Bar graph display
• Rate of change function
• Peak hold function
• High speed update function (100/sec)
• 2nd load cell input channel
• 3rd and 4th load cell input channels (810 only)
• Digital outputs (5 – 16) for setpoints
• 3rd auxiliary serial port (810 only)
• Single and dual channel analog output options (dual on 810 only)
• Expansion board option (810 only)
• 2-, 4- and 16-channel relay modules (16-channel on 810 only)
• RS-485 communication option
• Remote keyed switch for accessing supervisor mode
• Panel mounting kit, or Wall mounting kit (standard on 800)
• NEMA 4X reinforced fiberglass or stainless steel batching enclosure
• Start/Run/Stop batching switch
• Allen-Bradley Remote I/O Network Interface
®