18H Heating Roller Warmup Failure
19H Abnormally Low Heating Roller Temperature
1AH Abnormally High Heating Roller Temperature
1BH Faulty Thermistor
Phaser 6115MFP Multifunction Product Service Manual
Troubleshooting Procedure Table (Continued)
Step Action and Questions
4
Check the Rack Positioning sensor at
PJ5, pin 11. Is the sensor on?
5
Replace the Engine Control Board
(page 8-57).
Applicable Status Code
18H:
Heating Roller Warmup Failure
Applicable Status Code
19H:
Abnormally Low Heating Roller Temperature
Applicable Status Code
1AH:
Abnormally High Heating Roller Temperature
Faulty thermistor in the Fusing Unit.
Applicable Status Code
1BH:
Faulty Thermistor
Initial Actions
Remove power from the system and reboot.
Print a test page.
Error Codes and Messages
Yes
No
Go to Step 6.
Replace the
sensor
(page 8-112). If
the problem
persists, go to
Step 6.
Complete.
3-23