ADF CD Registration

Phaser 6115MFP Multifunction Product Service Manual
6.
Press the Menu/Select key, adjust the setting value using the +/- key, and
then press the Menu/Select key to validate the setting.
7.Repeat steps 4 through 6 until the length of line A falls within the specified
range.
8.
If dimension A on the copy falls outside the specified range:
a.
Increase the setting value if dimension A falls short of the specified
range.
b.
Decrease the setting value if dimension A exceeds the specified
range.
Adjusts the image scan start position in the CD direction of the Auto
Document Feeder Unit.
When to Use:
When a new Auto Document Feeder Unit is mounted.
Specification:
20mm +/- 1.0mm
Adjustment Range:
The default setting is 0.00.
Adjustment Range: -5.00 (-5.00 mm) ~ "0.00 (0.00 mm)" ~ +5.00 (+5.00
mm)
Procedure:
1.
Prepare a chart (A4S or 11 x 8 1/2S) by drawing a reference line on a
sheet of paper at a position 20 mm away from the edge as illustrated
below
2.
Enter the SERVICE MODE.
3.
Select [ADF CD REGIST] of [1 ADJUST] and press the Menu/Select key.
4.
Load the test chart in the ADF and press the Start key.
Adjustments and Print Function Settings
Width A: 20 mm
s6115-362