Resource block error messages

Error conditions found in the Resource block.
Table 5-9: Resource Block BLOCK_ERR Messages
Condition Name
Block configuration error
Simulate active
Power up
Out of Service
Device Fault State
5.5

Transducer block error messages

Error conditions found in the transducer block.
Table 5-10: Transducer Block BLOCK_ERR Messages
Condition Name
Other error
Out of Service
Rosemount 2230 Graphical Field Display
Description
Configuration Error is used to indicate that you have selected an
item in FEATURES_SEL or CYCLE_SEL that was not set in
FEATURES or CYCLE_TYPE, respectively.
This indicates that the simulation switch is in place. This is not an
indication that the I/O blocks are using simulated data.
This bit is set when resource block is in initialization state or at
the time of device power up.
The actual mode is out of service.
Set and cleared using SET_FSTATE and CLR_FSTATE.
Description
Set whenever XD_ERROR is non-zero. See also
status in AMS Device
Manager.
The actual mode is out of service.