Emerson Rosemount 2230 Reference Manual page 95

Graphical field display
Hide thumbs Also See for Rosemount 2230:
Table of Contents

Advertisement

Reference Manual
00809-0100-2230
5. Select Configure → Alert Setup.
6. Select the desired tab (FF I/O Board or Rosemount 2230 Graphical Field Display).
7. Configure alerts for the different error types.
8. Once the configuration is finished, click the Send button to save the current alert
Related information
Viewing active alerts in AMS Device Manager
Alert default settings
4.16.1
Alert default settings
The following default settings are used for the FF I/O Board and the Rosemount 2230
Graphical Field Display. You may configure error types in a different way if you like. For
example, the Internal Temperature Out of Limits error is configured as a Out of
Specification alert for the Rosemount 2230 by default. The Alert Setup window allows you
to enable the alert as Failed or Function Check instead.
Rosemount 2230 Graphical Field Display
You may change the configuration for each error type by selecting the appropriate
check box to match your requirements. Note that it is possible to map an error
condition to several alert categories if desired.
Note that when simulating alerts, only alerts which are setup according to the
default configuration will be simulated.
setup.
Configuration and operation
March 2021
95