Status LED
The status LED indicates error codes using different blinking sequences. In normal
operation the LED flashes every other second. When an error occurs, the LED flashes a
sequence that corresponds to a code number followed by a five second pause. This
sequence is continuously repeated.
Communication LEDs
Tankbus communication is indicated by a pair of LEDs, see
the Tankbus cables you can check the communication status with the LEDs.
Reset button
You may use the Reset button to force a restart of the Rosemount 2230 display. Restarting
the Rosemount 2230 has the same effect as switching off and on the power supply.
The Restart option will connect the Rosemount 2230 display to the Rosemount 2410 Tank
Hub and perform start-up tests of software and hardware.
Related information
Device error signals
3.6

DIP switches

The Rosemount 2230 is equipped with four DIP switches as illustrated in
Figure 3-10: DIP Switches
The switches control the following settings:
Table 3-2: Rosemount 2230 DIP Switches
Number
1
2
3
4
Rosemount 2230 Graphical Field Display
Name
Description
Simulate
Enables simulation for test of Field Diagnostics in open FF
systems.
Write Protect
Enables write protection of configuration data.
Spare
Not used.
Spare
Not used.
Installation
March 2021
Figure