Table C-1: Resource Block Parameters
Index
Parameter
Number
64
FD_RECOMMEN_ACT
65
FD_EXTENDED_ACTIVE
66
FD_EXTENDED_MAP
67
COMPATIBILITY_REV
68
HARDWARE_REVISION
69
SOFTWARE_REV
70
PD_TAG
71
DEV_STRING
72
DEV_OPTIONS
73
OUTPUT_BOARD_SN
74
FINAL_ASSY_NUM
75
DOWNLOAD_MODE
76
HEALTH_INDEX
77
FAILED_PRI
78
RECOMMENDED_ACTION
79
FAILED_ALM
80
MAINT_ALM
81
ADVISE_ALM
Rosemount 2230 Graphical Field Display
(continued)
Description
This parameter is a device enumerated summarization of the most
severe condition or conditions detected. The DD help should describe by
enumerated action, what should be done to alleviate the condition or
conditions. 0 is defined as Not Initialized, 1 is defined as No Action
Required, all others defined by manufacturer.
An optional parameter or parameters to allow the user finer detail on
conditions causing an active condition in the FD_*_ACTIVE parameters.
An optional parameter or parameters to allow the user finer control on
enabling conditions contributing to the conditions in FD_*_ACTIVE
parameters.
This parameter is used when replacing field devices. The correct value of
this parameter is the DEV_REV value of the replaced device.
Hardware revision.
Software revision of source code with resource block.
PD tag description of device.
This is used to load new licensing into the device. The value can be
written but will always read back with a value of 0.
Indicates which miscellaneous device licensing options are enabled.
Output board serial number. For the Rosemount 2230 this is the same as
Main Label Device ID which can be found on the main label that is
attached to the housing.
Final assembly number given by manufacturer.
Gives access to the boot block code for over-the-wire downloads.
0 = Uninitialized
1 = Run mode
2 = Download mode
Parameter representing the overall health of the device, 100 being
perfect and 1 being non-functioning. The value is based on the active
PWA alarms.
Designates the alarming priority of the FAILED_ALM and also used as
switch b/w FD and legacy PWA. If value is greater than or equal to 1 then
PWA alerts will be active in device else device will have FD alerts.
Enumerated list of recommended actions displayed with a device alert.
Alarm indicating a failure within a device which makes the device non-
operational.
Alarm indicating the device needs maintenance soon. If the condition is
ignored, the device will eventually fail.
Alarm indicating advisory alarms. These conditions do not have a direct
impact on the process or device integrity.