Reference Manual
00809-0100-2230
A.4.2
Dimensions (width x height x depth)
150 x 120 x 78 mm (5.9 x 4.7 x 3.1 in.)
A.4.3
Weight
1.3 kg (2.9 lbs)
A.5
Environment
A.5.1
Ambient temperature
-20 to 70 °C (-4 to 158 °F)
A.5.2
Storage temperature
-30 to 85 °C (-22 to 185 °F)
A.5.3
Humidity
0-100% relative humidity, non-condensing.
A.5.4
Ingress protection
IP 66 and 67 (NEMA
A.5.5
Metrology sealing possibility
Yes
A.5.6
Write protect switch
Yes
A.5.7
Transient / built-in lightning protection
According to IEC 61000-4-5, level 1 kV line to ground.
Complies with IEEE 587 Category B transient protection and IEEE 472 surge protection.
A.6
Installation and configuration
The Rosemount 2230 Graphical Field Display can be installed either on the tank roof or at
the foot of the tank for a flexible and convenient read-out of tank data.
Cabling can be daisy-chained via the Rosemount 2230 terminals to other devices on the
Tankbus. A terminator is required at each end of the Tankbus to ensure the fieldbus
Rosemount 2230 Graphical Field Display
®
4)
Specifications and reference data
March 2021
139