International - Emerson Rosemount 2230 Reference Manual

Graphical field display
Hide thumbs Also See for Rosemount 2230:
Table of Contents

Advertisement

Reference Manual
00809-0100-2230
B.6

International

B.6.1
I7 IECEx Intrinsic Safety
Certificate
Standards
Markings
Entity parameters
FISCO parameters
Specific Conditions for Safe Use (X):
1. The non-metallic parts incorporated in the enclosure of this equipment may
2. The enclosure contains aluminum and is considered to present a potential risk of
3. The Rosemount 2230 Graphical Field Display will not pass the 500Vrms dielectric
4. To maintain ingress protection ratings IP66 and IP67, PTFE tape or pipe dope is
Rosemount 2230 Graphical Field Display
IECEx FMG 10.0021X
IEC 60079-0:2011, IEC 60079-11:2011
Ex ia IIC Ga T4 (-50 °C ≤ Ta ≤ +70 °C); IP66/IP67
Ui
30 V
17.5V
generate an ignition-capable level of electrostatic charge. Therefore particularly
when it is used for applications that specifically require Division 1 and Group II, Zone
0 located equipment, the equipment shall not be installed in a location where the
external conditions are conducive to the build-up of electrostatic charge on such
surfaces. Additionally, the equipment shall only be cleaned with a damp cloth.
ignition by impact or friction. Care must be taken during installation and use to
prevent impact or friction.
strength test and this must be taken into account during installation.
required for cable entries and blanking plugs.
Ii
Pi
300 mA
1.3 W
380 mA
5.32 W
Product certifications
March 2021
Ci
Li
2.1 nF
1.1 µH
N/A
N/A
151

Advertisement

Table of Contents
loading

Table of Contents