Setting The Serial Port Parameters - 3Com LINKBUILDER 3C18500 User Manual

Msh management module
Table of Contents

Advertisement

configured to use the same Community String otherwise it will
ignore the traps.
Throttle
receiving lots of traps at once, you can configure the Chassis to
transmit traps with a delay in between each successive trap
transmission. If several traps are generated at once, they will be
transmitted with the specified delay in between each transmission.
The default value is 100, which gives a 0.1 second delay. The unit of
throttle is one milli-second.

Setting the Serial Port Parameters

If you alter the serial port parameters you will terminate any existing
RS232 session with the management facility when you exit the screen.
Ensure that the remote end of the RS232 connection is set to the new
configuration so that you will still be able to access the facility from it
when you change the Serial Port parameters.
Figure 5-14 RS232 Port Setup Screen
Connection Type
Select REMOTE if you want to manage the chassis via a modem.
DCD Control and DSR Control are automatically ENABLEd even if
these options are not selected through the facility. Otherwise leave
this parameter at the default setting.
DUA1850-0AAA05
To prevent a remote network management station
OK
LOCAL / REMOTE
MSH Setup
CANCEL
5-21