Only belts with adequate leakage resistance (< 10
a protective cover a risk analysis must be carried out to ensure that it cannot represent
a fire or explosion hazard. The risk analysis must be carried out by the manufacturer
of the protective cover.
On belt pulleys the correct belt tension must be adhered to (see orderspecific
dimensioned drawing).
All addon parts must satisfy the requirements in Directive 94/9/EC.
Simple electrical means (such as monitoring devices, switches, Pt 100 resistance)
without identification in accordance with Directive 94/9/EC are to be connected
intrinsically safely by suitable isolation amplifiers.
When the gear unit is incorporated in plant or machinery, the manufacturer of such
plant or machinery must ensure that the contents of these instructions are
incorporated in his own instructions.
The coating must not carry an electrostatic charge!
The operator must ensure that highly effective mechanisms which can set up a charge
in the coating are safely avoided.
•
Removed safety equipment must be reinstalled prior to starting up.
•
Notices attached to the gear unit, e.g. rating plate, direction arrows etc., must always be observed.
They must be kept free from dirt and paint at all times. Missing plates must be replaced.
•
Screws which have been damaged during assembly or disassembly work must be replaced with new
ones of the same strength class and type.
•
Spare parts should always be obtained from Siemens (refer also to section 11).
3.2
Environmental protection
•
Dispose of any packing material in accordance with regulations or separate it for recycling.
•
When changing oil, the used oil must be collected in suitable containers. Any pools of oil which may
have collected should be removed at once with an oilbinding agent.
•
Preservative agents should be stored separately from used oil.
•
Used oil, preservative agents, oilbinding agents and oilsoaked cloths must be disposed of in
accordance with environmental legislation.
•
Disposal of the gear unit after its useful life:
─ Drain all the operating oil, preservative agent and/or cooling agent from the gear unit and dispose
of in accordance with regulations.
─ Depending on national regulations, gearunit components and/or addon parts may have to be
disposed of or sent for recycling separately.
BA 5030 en 02/2013
19 / 96
9
Ω ) must be used. Before fitting