Control With Fb 79; Assignment Of The Interfaces Relevant To Profinet Io - Siemens SIMATIC MV540 H Operating Instructions Manual

Optical identification
Hide thumbs Also See for SIMATIC MV540 H:
Table of Contents

Advertisement

Process interfacing via an automation system (PLC, PC)

9.4 Control with FB 79

9.4
Control with FB 79
Principle of data transmission via PROFINET IO
The following figure shows the interfaces of the optical reader that are relevant for data
transmission via PROFINET IO (FB 79).
Figure 9-3
Note
Relevant bytes of the user data
Bytes 1 to 31 of the "Send" user data interface are relevant. Only bytes 1 to 4 of the
"Receive" user data interface are relevant.
9.4.1

Assignment of the interfaces relevant to PROFINET IO

Control/status byte
Table 9- 33
Bit
0
1
126
Principle of data transmission via PROFINET IO (FB79)
Assignment of control bytes (input signals)
Signal
Description
DISA
Disable
Disables manual keyboard input, program selection and program sav-
ing, error acknowledgment, starting the optical reader
SEL0
Select 0
1)
Program selection bit 0
Operating Instructions, 06/2018, C79000-G8976-C494-01
SIMATIC MV500

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic mv540 sSimatic mv560 x

Table of Contents