Prepayment Mode; Display And Navigation Structure In Prepayment Mode; Overview - Landis+Gyr E470 Series User Manual

Hide thumbs Also See for E470 Series:
Table of Contents

Advertisement

Prepayment mode

15
Prepayment mode
15.1

Display and navigation structure in prepayment mode

15.1.1 Overview

D000058620 en a – E470 Series 3 SMETS2 100 mm – ZCX310 – User Manual and Functional Description
Issue 1.2
Figure 28 shows the prepayment mode display and navigation structure.
The main components of the display structure are:
Default display – In prepayment mode the default display is the total meter
index in kWh for active import (see section 15.3).
All segment display – After viewing the initial default the next display
shown in the sequence is the all segment display check (see section
15.4).
Tariff display list – The tariff display list is accessed from the default
display by holding button B and then navigating through the individual items
by further presses of button A. The tariff list displays information for tariff
TOU registers, tariff block counters and tariff TOU block registers (see
section 15.5).
PIN enabled – The PIN display if configured requires the user's previously
configured PIN to be entered to gain access to further displays held by
the meter. This is a feature to ensure consumer data privacy if enabled
(see section 15.6).
Prepayment mode status – Accessible from the all segment display using
button A. (NOTE that access can also be PIN protected). The display
will show the current prepayment status of the meter (see section
15.7).
Boost menu – The boost menu is accessed via a short press of the B
button when viewing the total active import display (see section 15.8).
Customer menu – The customer menu is accessed via long press of the B
button when viewing the credit status display. The customer menu
enables the following functionality;
PIN management
Viewing of Event Log
Viewing of Power Log
Rolling display list – a list of meter values (rolling registers and PIN
displays) accessible from the credit status display holding button A and
then navigating through the individual items by further presses of
button A.
Supply control – The supply control switch management can be accessed
from the prepayment status display by pressing the B button. The
credit status will define this access (see section 14.11). If PIN
protection is enabled, then PIN entry is required before access is
granted (see privacy PIN entry dialogue structure shown in Figure 20).
Emergency credit / add credit – The emergency credit and add credit
entry screens are accessed from the prepayment status menu, the
user can invoke emergency credit or enter a payment code.
Service Menu – The service menu is only accessible by removal and
replacement of the meter terminal cover, and is only for the access of
the utility meter or test engineers.
The service menu allows the following actions to be performed:
101/143
© Landis+Gyr

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3 smets2

Table of Contents