6.5.4.5
Supplier Contact Details Check
Step
Step entry
number
action
Total Active
1
Import
Navigate to
the Credit
2
Mode Status
display
Access rolling
3
register
display list
© Landis+Gyr
Note that the following sequence does not include any dialogues
associated with entering the Privacy PIN on the meter as it is assumed that
the privacy pin will not have been set immediately following device
installation and commissioning. The all test display has also been omitted
although it may be shown depending on the status of the display and
previous button presses.
Step Description
The normal default display of Total
Active Import should be displayed
on the meter.
Press button A briefly (< 2 s). To
access the credit mode status
display (example shown).
From the status display Press and
hold Button A (for >2 seconds) to
access the rolling register display
list. Then press button A several
times to navigate to the Supplier
Contact Details Display The
installation agent can check that
the correct supplier details have
been configured on the meter
during the installation process
NB: A change request is being raised that will move the Supplier Contact
Details display to the main credit display sequence, immediately after the
Active Tariff and Active energy import (+A) Total displays. This document
must be updated on delivery of the change to reflect the new position.
D000058620 en a – E470 Series 3 SMETS2 100 mm – ZCX310 – User Manual and Functional Description
Issue 1.2
Display
R a t e
import
C r e d i t M o d e B a l
import
import
S u p p l i e r A x x x x x x x
Installation and Commissioning
X X A c t I m p
0 0 0 0 0
kWh
£ 0 . 0 0