Electricity Meters BS/IEC/MID
Residential
Date: 14.01.2015
Filename: D000044352 E230 ZxR100xC and ZMR100xR User Manual en g.docx
© Landis+Gyr
E230 Residential Electricity Meter
ZxR100xC/ZMR100xR
User Manual
D000044352 en g

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E230 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Landis+Gyr E230

  • Page 1 Electricity Meters BS/IEC/MID Residential ZxR100xC/ZMR100xR E230 Residential Electricity Meter User Manual Date: 14.01.2015 Filename: D000044352 E230 ZxR100xC and ZMR100xR User Manual en g.docx © Landis+Gyr D000044352 en g...
  • Page 2 Section 6.7.4 Reset of maximum demand: MD register reset procedure updated. Section 6.8 Billing (stored values) (ZMR100xR only): new section added. Section 6.8.1 Unit suppression: new section added. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 3 Landis+Gyr makes no warranty, representation or guarantee regarding the performance, quality, durability or suitability of the products for any particular purpose. To the fullest extent permitted by law Landis+Gyr disclaims (1) any and all liability arising out of the use of the product, (2) any and all liability, including, but without limitation to, special, consequential and indirect damages and losses, and (3) any and all implied warranties, including, but without limitation to, fitness for purpose and merchantability.
  • Page 4: Table Of Contents

    Introduction ........................29 Materials and tools required ..................... 29 Mounting the meter ......................30 Connecting the meter ....................... 31 Final checks before applying power ................. 32 © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 5 Energy consumption plus green energy generation ..........65 6.13 Communication interfaces ....................66 6.14 Security system ........................ 67 6.14.1 Access level 3 (ZMR100xR only) ................68 D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 6 Formatted commands and error codes ................78 Decommissioning and disposal ................... 79 Terms and abbreviations ....................80 10.1 Acronyms .......................... 80 10.2 Units ..........................81 10.3 Standards ......................... 82 © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 7: About This Document

     A detailed description of the tasks to be performed during the entire life-cycle of the meter (configuration, installation, commissioning, operation, maintenance and disposal). D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 8 “For more information on safety issues, see section 3 Safety.” Terms and abbreviations A list of terms and abbreviations used in this document is available at the end of this document. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 9: Introduction

    They are used according to the technical specifications stated in the respective data sheets and in conjunction with this document. D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 10 Any other application of these meters is not considered use for the intended purpose. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 11: Type Designation

    In this user manual, the extensions found in the type designation for the tariff functions and pulse transmissions are not mentioned unless they provide a better understanding. D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 12: E230 Zmr1X0Ar/Cr

    In this user manual, the extensions found in the type designation for the tariff functions and pulse transmissions are not mentioned unless they provide a better understanding. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 13: Technical Details

    In accordance with MID Class A Approx. 15 mA to 125 A Maximum Measuring Range Load Capacity 125 A Measurements 10,000 A (standard 30 x I Short Circuit < 10mS D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 14: Frequency Values

    10 V/m & 30 V/m Dwell Time Line Transients (burst) IEC 61000-4-4 Current and Voltage Circuits 4 kV Auxiliary Circuits > 40V 2 kV Rise Time 5 ns © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 15: Voltage Interruption And Restoration

    <5 s Voltage after 2.4.10 Output values Display Liquid Crystal Display (LCD), high Type performance Super-Twisted Nematic (STN) technology Character Size (main digits) 10 mm D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 16 Supply Voltage (typ.) 24 V Supply Voltage (max.) 50 V Current 10 mA DC Pulse Length Configurable (10 ms – 1000 ms) Maximum Line Length 1000 m © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 17: 2.4.11 Control Inputs

    For the necessary hardware and software, please contact the Landis+Gyr Metering Sales Team who will be happy to assist. D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 18 0047.62 kW 14.7.0 50.2 Hz 32.7.0 239 V 52.7.0 234 V 72.7.0 240 V 0.2.2 0.1.0 C.61.0 0000 C.61.2 00000000 min Figure 2. Data readout example © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 19: Safety

    For this purpose, Landis+Gyr provides training on a variety of products and solutions. Please contact your local Landis+Gyr representative if interested. D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 20: Safety Regulations

    Currents up to 100 A: a cable with a minimum 25 mm cross- sectional area.  Currents up to 125 A: a cable with a minimum 35 mm cross- sectional area. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 21: Mechanical Description

    Figure 3. View of the E230 ZxR110CC meter 1. Reactive test output 2. Display 3. Display button 4. Active test output 5. Alert LED 6. Optical interface D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 22 Figure 4. View of the E230 ZMR120CR meter 1. Reactive test output 2. Display 3. Display button 4. MD (Maximum Demand) button 5. Active test output 6. Alert LED 7. Optical interface © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 23: Meter Construction

    Comply with DIN 43857 Width 182.4 Height (with standard terminal cover) Height (with extended terminal cover) 239.1 Height (with extra extended terminal cover) 346.1 Depth 65.5 D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 24: Faceplate Details

    The meters serial number and barcode will be laser marked onto the front of the meter case. Serial numbers are allowed with up to 16 characters. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 25: Purpose Of Use

    A with steel terminals). The type designation informs you about the meter’s functionality. The extensions define the features/functions of the meter, some of which are optional. D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 26: External Connection Diagrams (Ecd)

    4.2.1 Single-tariff version Figure 7. E230 3-phase 4-wire network 4.2.2 Single-tariff version with twin pulse outputs Figure 8. E230 3-phase 4-wire network, 2 pulse outputs © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 27: Multi-Tariff Version With Pulse Input, Pulse Output And Cs Interface

    27/84 4.2.3 Multi-tariff version with pulse input, pulse output and CS interface Figure 9. E230 3-phase 4-wire network, 1 pulse input, 2 pulse outputs and CS 4.2.4 Multi-tariff version with two pulse inputs, two pulse outputs and CS interface Figure 10. E230 3-phase 4-wire network, 2 pulse inputs, 2 pulse outputs and D000044352 en g –...
  • Page 28: Multi-Tariff Version With One Pulse Input, One Relay Output And Rs485 Interface

    Mechanical description 4.2.5 Multi-tariff version with one pulse input, one relay output and RS485 interface Figure 11. E230 3-phase 4-wire network, 1 pulse input, 1 relay output and RS485 4.2.6 Multi-tariff version with four pulse inputs and RS485 interface Figure 12. E230 3-phase 4-wire network, 4 pulse inputs and RS485 ©...
  • Page 29: Installation And Commissioning

    Suitable-sized screwdriver.  Sealing pliers (if required) to affix company seal.  Suitable drilling machine, if required.  Test equipment as supplied and as required. D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 30: Mounting The Meter

    4. Drill the holes for the fixing screws 5. Unscrew and remove the meter terminal cover 6. Fix the meter to the meter board or other supplied surface with the fixing screws © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 31: Connecting The Meter

    4. Follow the numbering system as shown on the ECD, which is located on the inside of the terminal cover. D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 32: Final Checks Before Applying Power

    Caution Some of the aids described here are not available depending on the version for a specific country. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 33: Installation Mode

    .MAP110 meter support tool (see formatted commands “Enable Test Mode” and “Disable Test Mode”). D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 34: Operation

     IRMS and VRMS per phase  Power Factor per phase and for all phases  kW, kVAr and kVA per phase, summed and total © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 35: Example Displays

    ID1.4 Manufacturing ID (8 characters) ID1.4 0.0.3 ID 2.1 Identification Number 2.1 ID2.1 C.1.0 ID 2.2 Identification Number 2.2 ID2.2 C.1.1 IEC Device Address C.90.1 D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 36 TT RT C.61.1 Terminal Tamper Cumulative Time TT CT C.61.2 Meter Case Tamper Count TC R C.62.0 Meter Case Tamper Running Time TC RT C.62.1 © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 37 Active TOU ID (ZMR100xR only) AT ID 0.2.2 Passive TOU Activation Date (ZMR100xR only) PT AD C.2.7 Passive TOU ID (ZMR100xR only) PT ID 0.2.7 D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 38: Energy Efficiency Meter Displays (Zmr100Xc Only)

    In a reverse phase situation (e.g. L1-L3-L2), the phase power segments will flash. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 39 –P indicator is flashing, which indicates that there is an amount of reverse energy being measured, but it is less than the forward energy. Example B (OBIS code 1.8.1) D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 40 These indicators, along with the phase powered indicators (L1, L2, L3), battery monitor and rate indicators (see below) provide the user with a quick overall status of the meter. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 41: Total Registers

    Reactive positive total display Example E (OBIS code 3.8.1) Active forward total display Example F (OBIS code 1.8.1) Reactive negative total display Example G (OBIS code 4.8.1) D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 42: Rate Registers

    The energy direction indicators are incidental to this (and any other) display mode, and are showing current energy consumption (Reactive in anti-creep mode, Majority Forward with some Reverse Active energy in this example). © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 43: Instantaneous Values

    Examples of these are shown below: T-phase (L3) reactive power (+/- summed) Example L (OBIS code 191.7.3) R-phase (L1) active power (forward / reverse summed) Example M (OBIS code 36.7.0) D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 44 Instantaneous average current (across all 3 phases) Example P (OBIS code 12.7.1) Instantaneous power factor (individual phase; phase T (L3) in this example) Example Q (OBIS code 73.7.0) © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 45: Maximum Demand Displays

    In all the examples, kW has been measured. The meter can be configured to measure kVAr. Maximum demand rate 2 Example S Maximum demand total Example T D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 46: Alert / Report And Test Displays

    Some of the following options will also require the relevant hardware, which must be factory fitted. Terminal cover tamper count Example W (OBIS code 82.8.1) © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 47: Energy Registers

    All energy registers are incremented for every 1 Wh, VArh or VAh of energy consumed. The meter has up to six (in E230 ZxR100xC) or eight (in E230 ZxR100xC) user-defined energy registers (or channels), each of which can be configured to measure for example:...
  • Page 48: Push Button Operation

    Segments” are displayed (ZMR100xR only). The MD button is an optional feature and allows for fitment of a wire and ferule (or similar) utility seal. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 49: Tamper Detection

    Indicates that the battery voltage fell below a set threshold. Current Indicates that any phase imbalance current is below the % threshold of Max Current. D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 50 1, 2, above a set limit. 3 and 4 37, 38, Phase Indicates a reversal of polarity reversal L1, of the current coil. L2, L3 © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 51 Front cover Indicates that the front cover removal has been removed. D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 52: Meter Cover Opening (Optional Fitting)

    Current Imbalance (ZMR100xR only) With the exception of meter cover tamper, terminal cover tamper and DC field, all alerts/events have separate definable thresholds and include: © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 53: No Power Read (Optional Fitting)

    ToU (Time-of-Use) tables (ZMR100xR only) The E230 ZMR100xR’s ToU functionality provides a maximum of 16 output signals to switch:  Energy  Demand tariffs  Control loads D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 54 At each change of the date, the time switch checks whether or not the following day is a special day and selects the day table accordingly. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 55: Tariff Control (Zmr100Xr Only)

    Time of use signals  Voltage monitors  Anti-fraud inputs  Demand monitor  Power factor monitor Time-of-Use has up to 16 Time switch signals for controlling tariffs. D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 56: Load Control (Zmr100Xr Only)

    (e.g. if the period is 12 then the demand is calculated at 0, 12, 24, 36 and 48 minutes past the hour). © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 57: Rolling' Maximum Demand

     Display shows ‘rSt PASS’ to indicate successful acknowledgement of a manual reset. (If manual reset is not successful, the display will show ‘rSt FAIL’). D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 58: Billing (Stored Values) (Zmr100Xr Only)

    15.8.0 10 (000002.16*kvarh) 5.8.0 10 (000002.70*kvarh) 6.8.0 10 (000017.69*kVAh) 7.8.0 10 (000010.55*kWh) 8.8.0 10 (000002.22*kWh) 130.8.0 10 (000002.16*kvarh) C.8.0 10 (00000033) C.8.1 10 (00000000) Example Readout © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 59: Unit Suppression

    IEC readout. 6.8.1 Unit suppression IEC billing readout may be parameterised to suppress values to suit reading preference or simplify data capture for utility acquisition. D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 60: Mdtp (Manual Date Time Programming) (Zmr100Xr Only)

    Date* (0.9.2)  Time* (0.9.1)  ID1.1 (0.0.0)  ID1.2 (0.0.1)  ID1.3 (0.0.2)  ID1.4 (0.0.3)  ID2.1 (C.1.0)  ID2.2 (C.1.1) * ZMR100xR only. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 61 Figure 16. Date/time programming mode button operation Figure 17. Normal mode display Figure 18. Set mode display Figure 19. Program mode display D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 62 The Success/Fail message confirms the validity of the programmed data. A fail message will revert the display back to Display 1 in 5 seconds. Successful timeout is 10 seconds. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 63: Front Panel Optical Port

    Channel 1 Import, Q1+Q4 Q3 Q4 Q2 Q1 Channel 2 Export, Q2+Q3 Q3 Q4 Channels 3 Q2 Q1 to 6 (can be Q3 Q4 configured) D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 64: 6.12.2 Complete Four-Quadrant System

    Quadrants Direction Value Phase Unit Q2 Q1 L1,L2, Channel 1 Import, Q1-Q4 Q3 Q4 Channels 2 Q2 Q1 to 6 (can be Q3 Q4 configured) © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 65: 6.12.4 Import And Export Values

    Channel 4 Import, Q1+Q2 kVAr Q3 Q4 Q2 Q1 Channel 5 Export, Q3+Q4 L2+L3 kVAr Q3 Q4 Q2 Q1 Channel 6 Export, Q3+Q4 kVAr Q3 Q4 D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 66: Communication Interfaces

    Connection type: screwless terminals. Terminals are doubled up in order to facilitate the ability to connect in and out (loop) of the meter without compromising the connection quality. Designation Connection Ground © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 67: Security System

    Level 0 provides read access to all data, level 1 write access to non- critical data and level 2 write access to non-critical parameters. Figure 21. E230 ZxR100xC security levels Figure 22. E230 ZMR100xR security levels D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 68: Access Level 3 (Zmr100Xr Only)

    Reset Billing/MD period  Enable/Disable test mode  Reset Energy and Demand registers  Reset Error register  Reset Tamper Flags  Reset Fraud Detection © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 69 Read and set Billing (Stored Values) settings and parameters  Reset Alert indicator  Reset Billing period counter  Reset Operating Time registers  Reset Billing (Stored Values)  Reset Load Profile D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 70: Maintenance

    60 s 20 s 20 s 20 s 20 s 20 s 20 s ≥ 1 3 ph = balanced load 1 ph = single-phase load © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 71: Post-Installation Configuration Changes

    If none of the above are causing the fault, the meter should be disconnected as described in section 7.4, replaced if required as detailed in section 5, and returned to Landis+Gyr as described in section 7.5. D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 72: Disconnecting The Meter

    3. Package the meter to ensure no further damage can occur during transit. 4. Send the meter back to Landis+Gyr. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 73: Error Handling

    This error display is added to the end of the current display, if it is not already parameterised to display in the main display sequence. On the display of E230 meters, an error is shown as an eight digit hexadecimal value, i.e. the single digits may show values between 0 (no error code set) and F (all four error codes set).
  • Page 74 Register” (W2 C150) from EEPROM.) occurrence is not command using reliable. This error will .MAP110 or by power- only occur during the cycle. power-up sequence. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 75 Load Profile data may also be compromised. Maximum Demand will be calculated at configured intervals. Caused by the meter’s inability to read/write to RTC. D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 76 EEPROM. (No occurrence is not command using backup of reliable. Error will only .MAP110 or by power- registers occur during the power- cycle. available.) up sequence. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 77 F.F.0 on display and incorrect or corrupt readout by “Reset Error parameterisation. Register” (W2 C150) command using .MAP110 or by power- cycle. 00000040 UNUSED D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 78: Formatted Commands And Error Codes

    999A0999 in the address, the response will be ER30). If none of the above cases are true and there are still problems with communication, “NAK” (not acknowledged) is sent in response. © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 79: Decommissioning And Disposal

    Sorted and delivered to metal recycling plants Plastic components Sorted and delivered to re-granulation if at all possible Batteries Removed from meter and delivered to specialised recycling plants D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 80: Terms And Abbreviations

    Liquid Crystal Display Light Emitting Diode Maximum Demand Metering Industry Directive No Power Read The Office of Gas and Electricity Markets OFGEM Photo-transistor Reverse Energy Detected © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 81: Units

    (unit of resistance) mΩ millisecond Newton meter (unit of torque) Degree Celsius (unit of temperature) °C Rated supply voltage of meter Rated external switch voltage Volt D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 82: Standards

    Metering equipment (class indexes A, B and C) EN 50470-3 Electricity metering equipment (a.c.). Particular requirements. Static meters for active energy (class indexes A, B and C) © Landis+Gyr D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual...
  • Page 83 Terms and abbreviations 83/84 D000044352 en g – E230 Residential Electricity Meter – ZxR100xC/ZMR100xR – User Manual © Landis+Gyr...
  • Page 84 Contact: Landis+Gyr AG Theilerstrasse 1 CH-6301 Zug Switzerland Phone: +41 41 935 6000 www.landisgyr.com...