Control Elements; Metrology Led; Lcd Display - Landis+Gyr E470 Series User Manual

Hide thumbs Also See for E470 Series:
Table of Contents

Advertisement

24/143
4.4

Control elements

4.5

Metrology LED

4.6

LCD display

© Landis+Gyr
18 - Property designation
19 - Meter family designation
The E470 meter features two push buttons (see Figure 3):
Display button A (green) primarily used for scrolling through configured
menus configured for the meter and selecting functions.
Display button B (grey) used for locally re-connecting the supply and
other display menu functions.
The E470 features a single red colour metrology LED for indicating active
or reactive energy pulses. The pulse constant (number of pulses per en-
ergy unit measured) of the metrology LED and class for active and reactive
measurement is laser etched on the face plate above the metrology LED.
By default, the metrology LED will be set to the following conditions (during
manufacture):
The pulse constant is set as 1000 imp/kW(Var)h (in accordance with
MID Class B; IEC Class 1)
The pulse length is set to 20 ms.
By default, the metrology LED indicates active energy.
Below starting current, the metrology LED is permanently lit to indicate that
the meter is in an 'anti-creep' status and the registers do not increment.
The LED remains lit until the meter current is increased in a forward
direction beyond the starting current.
The E470 meter features a custom segmented liquid crystal display (LCD,
see Figure 5.
export
import
£
7
6
5
2
Figure 5
Basic layout of the liquid crystal display (LCD)
1
16 starburst (14 segment) characters for showing display headers and meter
status
Currency indication including £, €, pence and cents per unit
2
3
Indication of units W, kW, Wh, kWh, var, kVar, Varh, VA, V, A, Hz
4
Maximum of 7 digits for showing register values
5
HAN signal indicator, showing when the device has joined a HAN and the
signal strength of the wireless link (see section 6.4).
6
Energy direction indication (import, export)
7
Icon for supply control switch / supply status
The LCD display is fitted with a back light to illuminate the display. The
back light operates following any button press for a time-period of 80
D000058620 en a – E470 Series 3 SMETS2 100 mm – ZCX310 – User Manual and Functional Description
Issue 1.2
1
4
Physical description
Cents/
2
Pence/
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3 smets2

Table of Contents