6.5.4

Meter Commissioned Check

6.5.4.1 Commissioned Check via Customer Menu
Step
Step entry
number
action
Start at the
default Total
1
Active Import
Display
Navigate to All
2
Segment
Display Check
Navigate to
3
Credit Mode
Status Display
Access the
4
Customer
Menu
© Landis+Gyr
Examples of the types of information that can be passed to the meter
during initial commissioning and configuration of the device and
subsequently checked using the display on the meter are as follows:
Meter Commissioned Check
Active Tariff Price
MPXN Check
Supplier Contact Details
The meter display does not change, or provide any feedback to the field
service agent whilst the configuration is applied, but it is expected that they
will receive confirmation that it has all been applied successfully via their
hand held unit. On receipt of such confirmation, the field service agent can
check that the meter has been successfully commissioned and all
configurations have been properly applied by querying the meter via a
series of button presses. The actions that can be taken are described
below.
This check can be performed either by entering the Customer Menu on the
meter or by accessing the Service Menu (requires removal of terminal
cover seal). Both methods are described below.
Note that the following sequence does not include any dialogues
associated with entering the Privacy PIN on the meter as it is assumed that
the privacy pin will not have been set immediately following device
installation and commissioning. If the PIN had subsequently been set then
the PIN entry dialogue would appear after step 2 below.
Step Description
The normal default display of Total
Active Import should be displayed
on the meter.
Press button A briefly (< 2 s) from
the default display. All segments of
the LCD are lit (display check).
Press button A briefly (< 2 s). To
access the credit mode status
display.
Press and hold button B longer (≥
2 s) to access the Customer Menu
on the meter. The first menu item
is Manage Pin?
D000058620 en a – E470 Series 3 SMETS2 100 mm – ZCX310 – User Manual and Functional Description
Issue 1.2
Display
R a t e
import
export
import
C r e d i t M o d e B a l
import
import
M a n a g e P I N ? A = N o
Installation and Commissioning
X X A c t I m p
0 0 0 0 0
kWh
Cents/
Pence/
£
£ 0 . 0 0
B = Y e s