15.6

PIN entry

© Landis+Gyr
Press button briefly (t < 2 s)
Press button longer (t ≥ 2 s)
30 second timeout from last button press –
returns display to Total active import display
Figure 29 Tariff display list
If PIN entry has been enabled, then after selecting the A button on the all
segment display the user is taken to the PIN entry screen
From the PIN entry screen the user is required to enter a pre-entered 4-
digit code.
The pin is entered using the A and B buttons
The A button is used to increment the numbers through 0-9
The B button moves to the next digit
Holding the B button for a long press (greater than 2 seconds) offers the
entered PIN details to the meter
After 3 seconds if a valid Pin entry has been accepted by the meter, then
the user can access the protected displays of the meter.
If an invalid PIN has been entered the user must repeat the sequence
detailed above.
D000058620 en a – E470 Series 3 SMETS2 100 mm – ZCX310 – User Manual and Functional Description
Issue 1.2
A
A
A
Prepayment mode
Tariff display
list
Tariff TOU registers
1 - 48
A
last
Tariff block
counters
A
last
Tariff TOU block
registers
last
A
To Total active import display