Functional overview
3.9

Customer privacy PIN

3.10

Non-Disablement calendar

3.11

Rolling register displays

3.12

Boost function

3.13

Remote commands

D000058620 en a – E470 Series 3 SMETS2 100 mm – ZCX310 – User Manual and Functional Description
Issue 1.2
When operating in credit or prepayment mode, the meter allows for the
protection of personal data items that may otherwise appear on the display.
The customer privacy PIN may be enabled, changed or disabled by the
user. For details see section 12.
When operating in prepayment mode, the supplier may configure a
calendar on the meter which defines non-disablement periods of time when
the meter will not disconnect the customer premises due to lack of credit
even if all available credit expires during that non-disablement period. For
details see section 10.
The rolling registers are used to provide the customers with a selection of
data that is not available on the default display cycle. These registers are
accessed by pressing and holding button A (≥ 2 s) whilst viewing the credit
or prepayment status display. The first register is then displayed.
Pressing button A again advances the display to the next register etc. until
the end of the list is reached.
After a timeout period of 30 seconds with no button presses the display
reverts to the default display. Some registers can only be viewed in certain
modes of operation.
If a customer privacy PIN is enabled then displays in the rolling register
sequence that are considered personal data will not be shown (they will be
skipped), unless the correct customer privacy PIN value has been entered
at the beginning of the session.
The E470 meter supports a boost function where if enabled can be
managed via the meter display. The boost function allows management of
the ALCS for additional time periods outside of the ALCS calendar settings.
The activate boost function will cause the ALCS configured as under
control of the boost function to close for 15,30,45 or 60 minutes, and then
revert to normal operation in accordance with the ALCS calendar.
The meter supports the cancelling of a boost period where the ALCS will
revert to normal operation in accordance with the ALCS calendar.
The meter also supports the extending an existing boost period where the
ALCS will remain closed for up to a maximum of 60 minutes for any single
active boost period.
The E470 meter supports remote communication over a ZigBee SEP
interface. This allows the meter to be controlled and monitored per the
protocols defined in the Great Britain Companion Specification (GBCS) in
accordance with SMETS2 operation.