3.3

Type designation

Type designation:
Type of meter
ZCX 1-phase 2-wire network (C-circuit, single phase)
Build option
S
SMETS
Connection type
3
Direct connection 100 A
Accuracy class
10
Combined meter active energy class 1 (IEC); B (MID),
reactive energy class 2 (IEC); A (MID
System interface
H
Intimate hub (SMETS2 firmware)
User interface
U0
No optical interface
U1
Optical interface
Local interface
L0
No local interface
L2
ZigBee
Supply control switch
D1
1-pole supply control switch (live only)
Relay outputs
4
2 A / 230 VAC non-latching potential free
Other options
1
Terminal cover and main cover removal detection
Meter variant
S2
SMETS1/2 Series 2 (120mm) hardware
S3
SMETS2 Series 3 (100mm) hardware
© Landis+Gyr
The exact hardware configuration of the E470 meter is expressed in a type
designation code. The type designation is used for ordering purposes and
can be read by the metering system.
Table 2
Type designation
D000058620 en a – E470 Series 3 SMETS2 100 mm – ZCX310 – User Manual and Functional Description
Issue 1.2
ZCX S
Functional overview
3 10
H U0 L2 D1. 4
1 S3