112/143

15.11 Reconnect supply load switch

15.12 Emergency credit and add credit dialogue

15.12.1 Emergency credit activation

© Landis+Gyr
V o l t a g e
0 0 0 2 3 0 . 2
import
A further press of button A will navigate to the next item.
C u r r e n t
0 0 0 0 0 . 8 4
import
Once the end of the list has been reached the A button press will navigate
the user to the credit status.
At any point the display will revert to the default display after a timeout
period of 30 seconds from the last button press.
Note
Display items that are configured in this list but are designated as PIN
protected will only be shown if a PIN has NOT been set or, if a PIN has
been set and the correct PIN has been entered by the user.
The user may require to access the enable supply display where a system
initiated disable of supply has been performed, or if the meter entered a
load limiting state.
Where PIN protection is not enabled the user is directed to the reconnect
display with a short press of button A, from the prepayment mode status
display.
If PIN is enabled by the meter configuration the meter will require the
entering of the PIN in the PIN entry dialogue before allowing access to the
prepayment mode status display.
If the user chooses not to reconnect the supply, then the A button should
be selected and the user is returned to the prepayment mode status
display.
For the reconnection of the supply the B button should be selected, the
meter will then reconnect the supply load switch and indicate the action
with a temporary reconnect message.
The emergency credit and add credit dialogues allow the activation of
emergency credit (when available) and the entry of a UTRN (payment
code).
When emergency credit is available selecting the A button from the
prepayment mode status display will direct the user to the emergency credit
display. If emergency credit is available for selection then the B button
should be pressed to accept emergency credit, the display will show that
emergency credit has been accepted and direct the user back to the
prepayment mode status display.
Selecting the A button will direct the user back to the add credit display.
D000058620 en a – E470 Series 3 SMETS2 100 mm – ZCX310 – User Manual and Functional Description
Issue 1.2