Troubleshooting (continued)
PROBLEM
Desired set mode item
• "EXPAND" item is set to OFF.
cannot be selected.
Programmed scan does
• Program scan edges are not programmed.
not start.
Memory or bank scan
• No or only one memory or bank channel is pro-
does not start.
grammed.
Charging indicator (BC-
• The temperature is too hot or too cold around the
164)
lights
red
while
charger (BC-164).
charging.

■ Optional CP-21LR fuse replacement

If the fuse blows or the charger stops functioning while oper-
ating with the optional CP-21LR, find the source of the prob-
lem if possible, and replace the damaged fuse with a new,
rated one (FGB 2 A) as shown at right.
POSSIBLE CAUSE
SOLUTION
• Turn "EXPAND" item ON.
• Program a pair of scan edge channels.
• Program at least 2 memory or bank channels
• Place the charger within the specified temperature
range (+5°C to +35°C; +41°F to +95 °F), then
charge the battery pack.
Fuse 2 A
13
MAINTENANCE
REF.
p. 49
p. 36
pgs. 24,
25
p. 8
13
74