Charging the battery (see Page 32)

5.3 Settings

The user may only perform the fine-tuning adjustments described in the following.
This fine-tuning should be carried out by attendants and only in the presence of the user. The user should sit
upright in the power wheelchair while adjustments are made.
Adjusting the position of the control panel (see Page 52)
Adjusting the belt lengths (see Page 16)
Adjusting the luggage carrier (see Page 52)
Further adjustments may be made only by qualified personnel
All parts of the product should be cleaned thoroughly before adjustments are made.

5.3.1 Changing control unit parameters

WARNING
Incorrect configuration settings
Falling, tipping over, collision due to programming errors
► Programming may only be performed by qualified personnel trained by the manufacturer. The manufacturer of
the product and the control unit manufacturer are not liable in case of damage caused by programming which
was not performed properly and/or which was not adjusted properly according to the user's abilities.
If necessary, the qualified personnel can adapt the preprogrammed wheelchair control unit and options to the con­
crete requirements of the user.

6 Use

6.1 Circuit breaker

INFORMATION
► Should the automatic circuit breaker deactivate repeatedly after activation for no discernible reason, contact
the qualified personnel.
► For shipping or when the power wheelchair is not being used for an extended period of time, the automatic
circuit breaker should be deactivated.
The automatic circuit breaker has to be activated before the power wheelchair can be switched on.
It is located under the seat between the drive wheels.
3

6.2 Armrests

The armrests offer the user additional support for the forearms.
To make getting into the wheelchair easier, the armrests can be folded up.

6.2.1 Folding away the arm supports

The arm supports can be folded up if necessary to make getting in from the side easier.
C1000 SF
Activating the circuit breaker
► Close the reset lever, which is at an angle (see
fig. 3, item 1).
→ The reset lever engages and the circuit breaker is
activated.
Deactivating the circuit breaker
► Press the pushbutton until the reset lever flips up at
an angle (see fig. 3, item 2).
→ The circuit breaker is deactivated.