12. Review the platform message log to verify SMS has received the message that the
component has been inserted, by typing:
sc% showlogs -F
Review the board insertion message. You will see a message similar to the one as
follows.
Jun 16 14:30:05 2003 sun15-sc0: esmd[7167]: [0 4824421445907014
NOTICE Boards.cc 1646] EXB at EXxx inserted
where xx is the expander assembly 0-17.
13. Close the Sun Fire E25K/E20K system cabinet access doors.
12.2.5

Powering On an Expander Board

G
Power on the expander by using the Sun Management Center or by typing the
following SMS command:
sc% poweron EXx
where x is the expander number 0-17.
12.2.6

Verifying an Expander Board

1. Using dynamic reconfiguration, configure the slot 0 and slot 1 boards occupying
the expander into the domain(s) by using the Sun Management Center or by
typing the following SMS command:
sc% addboard -d domain_id SBx
sc% addboard -d domain_id IOx
where SB is for slot 0 boards.
IO is for slot 1 boards.
x is the expander number 0-17.
12-8