5. Ensure SMS starts properly and no errors are reported in
/var/opt/SUNWSMS/adm/platform/messages.
Check the platform message log for any errors. Once the SMS starts, the following
message is displayed:
Oct 12 11:58:11 2001 star7sc1 fomd[348]: [8577 118844134283
NOTICE
FailoverMgr.cc 2785] SC configured as Spare
The spare could be either Spare or Main, depending on the state of the opposite SC.
6. Re-enable failover on the main SC by typing:
sc% setfailover on
7. Verify failover is enabled by typing:
sc% showfailover
SC Failover Status:
6-12
Sun Fire E25K/E20K Systems Service Manual • April 2004
ACTIVE