Table of Contents

Advertisement

Sun StorageTek™ 9985V

Storage System

Just the Facts
Sun Internal / Partner Version
October 09, 2007
Just the Facts
October 2007
1
Sun Confidential - For Internal Use and Authorized Partner Use Only

Advertisement

Table of Contents
loading

Summary of Contents for Sun Microsystems StorageTek 9985V

  • Page 1: Storage System

    Sun StorageTek™ 9985V Storage System Just the Facts Sun Internal / Partner Version October 09, 2007 Just the Facts October 2007 Sun Confidential – For Internal Use and Authorized Partner Use Only...
  • Page 2 Copyrights ©2005 Sun Microsystems, Inc. All Rights Reserved. Sun, Sun Microsystems, the Sun logo, Sun StorageTek, Sun Fire, Solaris, Solstice, Solstice Backup, Solstice DiskSuite, Netra, Sun Enterprise, Ultra, Sun Blade, Java, SunSpectrum, SunSpectrum Platinum, SunSpectrum Gold, SunSpectrum Silver, SunSpectrum Bronze, and SunSolve are trademarks or registered trademarks of Sun Microsystems, Inc.
  • Page 3: Table Of Contents

    Table of Contents Sun Internal / Partner Version............................1 October 09, 2007................................1 Copyrights..................................2 Positioning....................................5 Introduction..................................5 Key Product Attributes:...............................6 Main Hardware Features ..............................7 Main Software Features ..............................8 Key Messages ..................................11 Detailed Messages................................11 Key Messaging Statements with Respect to Current Product Line................12 Key Messaging Statements with Respect to Competition...................12 Hardware..................................16 Software ..................................17 Service / Warranty...............................18...
  • Page 4 Cluster Support..................................58 WWWW (What Works With What)..........................58 Microcode..................................59 RAID 10.....................................59 Features and Capabilities of the Sun StorageTek 9985V....................60 Multi-Vendor Host Platform Storage Pooling External LUN Mapping................60 Virtual Private Storage Machines (VPSM) ........................60 StorageTek 9985V Virtual Partitioning..........................61 Operating System Support ..............................62 Security .....................................62...
  • Page 5: October 09, 2007

    Proven Reliability Introduction The Sun StorageTek 9985V is the new version of the Sun StorageTek 9985 enterprise storage system. This is along the lines of similar technology refresh of the ST9990 with the ST9990V. Similar to the ST9990V, the Sun StorageTek 9985V will be based on 4th generation cross-bar architecture, 2nd generation embedded virtualization and Thin Provisioning.
  • Page 6: Key Product Attributes

    The ST9985V provides the industry’s most fully integrated combination of enterprise-proven hardware and software technologies that unify and simplify the delivery of universal data and storage services across heterogeneous storage platforms. Now customers can benefit from the industry’s most scalable storage solutions with superior performance and backed by a set of storage and data services that includes new thin provisioning with ST9900 Dynamic Provisioning™...
  • Page 7: Main Hardware Features

    o Controller based virtualization  Policy Driven Storage Management: o For data lifecycle management (DLM)  Thin Provisioning (Dynamic Provisioning): Improve storage utilization, provisioning and transparent capacity upgrades Main Hardware Features The ST9985V System provides an excellent combination of increased Performance, Scalability and Capacity. The following features will be available at time of announcement: * 13.3 GB/sec Aggregate System Bandwidth * 800,000 IOPS Maximum...
  • Page 8: Main Software Features

    Main Software Features All ST9985V software is levergeable from the ST9990V and offered as suite bundles or as stand alone. (Although the same software is usuable on multiple generations of the ST9900 systems, each generation has a separate and distinct set of part numbers. The ST9985V has is owns set of part numbers. This means that you can not use a SW part number from the ST9990V on the ST9985V.) ST9900 Basic Operating System (BOS) Suite replaces Device &...
  • Page 9: October

    The primary Basic Operating System interface, Device Manager software, utilizes an easy-to-use and intuitive graphical user interface to centrally manage the ST9985V along with all other Sun ST/SE9900 storage systems. A complete command line interface is also included. Through Device Manager software, Basic Operating System provides user, logical, physical, and host management views that enable provisioning and storage pooling for primary and secondary storage.
  • Page 10 ● Sun StorageTek 9900 Disaster Recovery Suite - Includes TrueCopy Sync+ HUR for both Open and Z/OS. Sun StorageTek 9900 TrueCopy Remote Replication provides data replication to other Sun StorageTek 9900 series subsystems over local or long distance connections. The added copies may be used to help enable disaster recovery, data mining, backup, testing, etc.
  • Page 11: Key Messages

    The Sun StorageTek 9985V provides storage virtualization. Customers can attach their existing storage systems from various vendors to the StorageTek 9985V which then appear as if they were part of the same system. This capability helps customer more effectively utilize and actually add value to their existing storage investments.
  • Page 12: Key Messaging Statements With Respect To Current Product Line

    “pulls” the copy from the primary, enabling “no-data-loss” replication and the ability to survive a downed link. (implemented by StorageTek 9900 Universal Replicator software) The Sun StorageTek 9985V system can also be a lower cost replication target for 3 data center disaster •...
  • Page 13 continue to do so against ST9985V. Similarly, the EMC InVista is positioned as a storage virtualization solution leveraging the integration with various FC switch vendors and, in particular, integration with Cisco directors. Based on industry analysts’ latest assessments of virtualization solutions, IBM SVC was proven to lack enterprise-level functionality and reliability and EMC’s InVista downgraded to caution due to lack of customer acceptance.
  • Page 14 Sun StorageTek 9985V – Key Features Customers are using the Sun ST9985V, Sun ST9990V, Sun ST9990, and ST9985 disk systems to support the largest and most critical data center environments. These systems provide performance, scalability and flexibility along with many powerful features that are not found in any other disk systems. These are some of the most valuable differentiating features.
  • Page 15 Set extension, but still lacks pull technology to off-load the local system and maximize available data bandwidth. EMC does not support Delta Resync for 3 data center failovers. IBM's Global Mirror replication product can maintain data consistency at the remote site, but requires local processing.
  • Page 16: Hardware

    Hardware This chart indicates, at a high level, what is available at GA (October 16, 2007) Feature ST9985 ST9985V First General Availability Release Performance 700,000 IOPS 800,000 IOPS Minimum: 4GB Minimum: 4GB Cache Memory Maximum: 64GB Maximum: 64GB Maximum Cache Path 8.5GB/second 8.5GB/second Bandwidth...
  • Page 17: Software

    ST9900 Series Software Suite Not all ST9985V features will be available at GA. The following will be available post GA(date TBD): C-NAS, UR 4X4X4 and UR 6X6, iSCSI Performance – Target of 800,000 IOPS vs. current ST9985 700,000 IOPS + performance improvements to local and remote replication, and external storage bandwidth.
  • Page 18: Service / Warranty

    -WARRANTY LEVEL AND LENGTH: Sun StorageTek 9985V System ------------------------------------- The official Sun StorageTek 9985V warranty statements are maintained at Sun's external web site at www.sun.com/service/support/warranty Sun warranty on Sun StorageTek 9900 Series including ST9985V system currently includes an enhanced warranty with: 3 years coverage.
  • Page 19 Installation -------------- StorageTek 9985V product include Sun StorageTek(SM) 9900 Installation Service, (9900 Installation) a basic install offering, for new subsystem (minimum 1 control unit) purchases. This installation is provided during normal business hours. Sun StorageTek 9900 Series Software...
  • Page 20 * Heterogeneous multi protocol connectivity * 48 FC, 24 ESCON, 24 FICON * High performance Open Systems, Multi-platform connectivity channels and NAS (Q4CY07) Mainframe and NAS connectivity * Better per port performance using faster processors * 4Gb/s FC ports Allows customers to consolidate, * Multi-platform storage pooling centrally manage and provide * Up to 96 PB of external storage...
  • Page 21 Device Management * Thin Provisioning * Host Storage Domains * Logical Boot Device (LUN 0) * Logical Partitioning (Storage LPAR) Performance Management Reduce TCO by simplifying storage * Performance Monitor Universal Storage Services management and reducing application * Volume Migrator service interruptions * Server Priority Manager * Tuning Manager...
  • Page 22: Positioning Statements With Respect To The Sun's Disk Array Families

    The Sun StorageTek 9000 product family is the right choice for customers who demand the absolute highest • levels of data availability and mainframe connectivity. With the introduction of the StorageTek 9985V, Sun's StorageTek 9900 family now consists of the ST9985, ST9985V, ST9990 and ST9990V addressing mid-range enterprise to the highest end of the data center market needs for both open systems and mainframe.
  • Page 23: Target Markets

    With conventional provisioning, it is difficult to know how storage inventory is configured or how much is utilized at any given time, which can prove costly and time-consuming. With the Sun StorageTek 9985V System, however, the boundaries of physical storage devices are abstracted to a virtual inventory of enterprise-class storage classes and resources that are easily managed, enabling quick and precise provisioning based on application workloads.
  • Page 24 Extreme Availability — All Sun StorageTek 9985V systems have been designed to ensure that the entire system has no single point of failure. Further, should a component in a StorageTek 9985V experience an outage, a redundant component takes over the tasks of a failing component until repaired. All of this is transparent from an application's perspective to the operation of the storage system.
  • Page 25: Partner Business Proposition

    No Hidden Costs — The Sun StorageTek 9985V system includes a wide breadth of standard features of any system in its class. With Sun StorageTek Enterprise Storage Manager, Sun StorageTek 9985V Availability Suite, and Sun-server based load balancing, this system comes pre-tested with the complete set of functions required to host today's business-critical application environments.
  • Page 26: Target Applications

    These environments require a storage system capable of performing both transaction-heavy and throughput-heavy I/O. The Sun StorageTek 9985V system can be scaled to optimize I/O request operations, data movement, or a combination of both. I/O optimization does not sacrifice data protection, making this system an ideal storage solution for messaging applications.
  • Page 27: Data Warehousing / Business Intelligence

    9985V system. Critical digital assets can be maintained on the Sun StorageTek 9985V and less critical digital assets can be migrated to lower-cost storage systems managed by the Sun StorageTek 9985V. Adding to this software support for hierarchical storage management, such as Sun's Storagetek SAM-FS and StorageTek QFS , and the ZFS File System products, the Sun StorageTek 9985V becomes the answer to an enterprise's information lifecycle management needs.
  • Page 28: Product Specifications

    Product Specifications Product Overview Sun StorageTek 9985V is a comprehensive and fully integrated enterprise storage services platform that enables customers to achieve the highest levels of availability and performance in the industry with the lowest TCO. It is an evolution of the ST9990 with refinements to existing technology and additional new functionality, with higher system performance to further differentiate it from the competition.
  • Page 29 depreciated, can attach their legacy storage to ST9985V externally and exploit the unique virtualization, storage partitioning, universal replication, and other new software tools with their legacy storage. At a later date when it is more financially beneficial to retire the legacy storage, the customer can migrate the data to ST9985V or any other platform within ST9985V’s external storage pool.
  • Page 30 virtual private storage machines are the perfect compliment to mainframe LPARs and together they provide workload isolation and optimum quality of service. This will be enhanced in the near future when FICON qualified to support external storage, along with Universal Volume Manager. This is not a statement that the ST 9990 V comes with internal SATA storage.
  • Page 31: Front View

    Disk Controller (DKC) Frame Disk Unit (DKU) or Disk Array Frame TOP VIEW 1046 mm 601 mm REAR VIEW FRONT VIEW 2001 mm Just the Facts October 2007 Sun Confidential – For Internal Use and Authorized Partner Use Only...
  • Page 32 TOP VIEW 1046 mm 601 mm REAR VIEW FRONT VIEW 2001 mm Just the Facts October 2007 Sun Confidential – For Internal Use and Authorized Partner Use Only...
  • Page 33 Here   i s   another   diagram  of   the   pr imary   and  secondary   rack   fo r   the   ST  9985  V Primary Rack     Secondary Rack Disk Chassis (DKU-R1) Disk Chassis (DKU-R0) Disk Chassis (DKU-R3) Additional...
  • Page 34: Hardware Architecture

    Power supply boundary Cluster 1 Cluster 2 Location Option3 Option1 Option1 Basic Option1 Option3 Option1 DIMM DIMM Logic PL DIMM DIMM Option1 Option2 Basic Option1 Option1 Option2 Option1 Location Front Hardware Architecture The ST9985V hardware is divided into the power supply section, controller section, and disk drive section in which disk drives are installed.
  • Page 35: Components Of The Controller Frame

    Channel I/F max.48-path Cluster1 Cluster2 (Option1) (Option3) (Option2) (Option1) (Option1) (Option2) (Option3) (Option1) (Basic) (Basic) 2path Cache Path Max. 8.5GB/s Hi-Star Net Cache Memory (max32GB) Cache Memory (max32GB) DKCBOX Cluster1 Cluster2 Cache DIMM FC-AL(4Gbps) Max. 60HDD/FCAL Max. 64HDD/FCAL Max. 64HDD/FCAL Max.
  • Page 36: Storage Clusters

    Storage Clusters Each controller frame consists of two redundant controller halves called storage clusters. Each storage cluster contains all physical and logical elements (for example, power supplies, channel adapters, disk adapters, cache, control storage) needed to sustain processing within the subsystem. Both storage clusters should be connected to each host using an alternate path scheme, so that if one storage cluster fails, the other storage cluster can continue processing for the entire subsystem.
  • Page 37: Nonvolatile Shared Memory

    Nonvolatile Shared Memory The nonvolatile shared memory contains the cache directory and configuration information for the ST9985V. The path group arrays (for example, for dynamic path selection) also reside in the shared memory. The shared memory is duplexed, and each side of the duplex resides on the first two SM cards, which are in clusters 1 and 2.
  • Page 38: Redundant Power Supplies

    500 meters (2750 feet) from the host(s). When configured with longwave FICON channel adapters, the ST9985V can be located up to ten kilometers from the host(s). If you need further FICON-related information, please contact your Sun Microsystems Systems representative.
  • Page 39: Disk Adapters And Back-End Directors

    Extended Serial Adapter (ExSA) (compatible with ESCON protocol). The ST9985V supports a maximum of ExSA serial channel interfaces. The ExSA channel interface cards provide data transfer speeds of up to 17 MB/sec and have 16 ports per pair of channel adapter boards. Each ExSA channel can be directly connected to a CHPID or a serial channel director.
  • Page 40 RAID group (7D+1P / 4D+4D) Fibre Port Number Fibre Port Fibre Loop (CL1) DKA Pair (CL2) Max. 64 HDDs per FCAL RAID group (3D+1P / 2D+2D) *1: A RAID group (3D+1P/2D+2D) consists of fibre port number 0, 2, 4, and 6, or 1, 3, 5 and 7. Figure 2.1 Conceptual Array Domain for the ST9985V BED Specifications...
  • Page 41: Service Processor (Svp)

    Service Processor (SVP) The ST9985V includes a built-in custom PC called the service processor (SVP). The SVP is integrated into the controller frame and can only be used by authorized Sun or Hitachi Data Systems personnel. The SVP enables the Sun or Hitachi Data Systems representative to configure, maintain, and upgrade the ST9985V. The SVP also collects performance data for all key components of the ST9985V to enable diagnostic testing and analysis.
  • Page 42: Disk Drives

    However, many customers have chosen to administer their systems remotely. If this occurs, then the security problem should be reframed as a general network security, administration, and integration issue. The issue may also be framed as a trade off between being secure on a private network versus opening up to an open corporate or even the public internet, which increases security risks.
  • Page 43 Recently ST9900 introduced concept of RAID concatenation. The benefit is to achieve the better performance in the backend. It allows striping the data across more disks. The disadvantage could be chances of more LDEV blockade if two or more HDDs are blocked (depends on RAID level used) With "RAID5 concatenation"on V06 code and higher, you can stripe across either two or four RAID5 7+1 parity groups (i.e.
  • Page 44 Physical tracks per physical cylinder (user area) (number of heads) Physical disk platters (user area) (numbers of disks) Sector length (byte) 520 (512) Seek time (ms) (read/write) 0.2/0.4 6.7/7.4 3.5/4.0 Average latency time (ms) 2.01 Internal data transfer rate 120 to 202 (MB/sec) Max.
  • Page 45 All disk drives can be replaced with no disruption to the system. With a maximum of 240 disk drives total, the total internal system raw capacity of a single StorageTek 9985V system is 69.2 TB (precise engineering measurement) or 72 TB in terms of a rounded up marketing measurement.
  • Page 46 As larger disk drive capacities are achieved (such as with 300 GB), the total amounts of data which would need to be recovered increases. The recovery time increases commensurately with the amount of data being recovered. As the recovery time lengthens, some customers are concerned that if a second disk drive fails, their ability to recover their data would be lost.
  • Page 47 RAID-5. A RAID-5 array group consists of four (3D+1P) or eight (7D+1P) disk drives. The data is written across the four (or eight) disk drives in a stripe that has three (or seven) data chunks and one parity chunk. Each chunk contains either eight logical tracks (mainframe) or 768 logical blocks (open).
  • Page 48 In Volume Migration operations (optimizing LDEV allocation), you cannot migrate an array group within a combined/striped group to another group. Volume Migration migrates all LDEVs in an array group to another array group. RAID 28+4 - Vertical Striping Raid 28+4 or Raid 14+2 - vertical striping is also known as Raid 5 concatenation in which two or four RAID5 (7D+1) parity groups are concatenated.
  • Page 49 Universal Storage Disk Array Unit Disk Array Unit Disk Array Unit Disk Array Unit Platform DKC Pair Pair Pair Pair 3390 -9 OPEN -3 3390 -3 3390 -9 OPEN -V OPEN -V Figure 2.2 Sample Device Emulation Intermix Comparing RAID levels The following are guidelines for comparing the characteristics of several RAID levels.
  • Page 50 20A trip values. All power supplies are dual power supplies and are hot-swappable Specific plug and receptacle configurations and part numbers are specified in the StorageTek 9985V installation guide. For environmentals, please go to the following URL: http://pts-storage.west/products/T99x0/documentation.html...
  • Page 51: Backup Mode (Usp V And Vm)

    Backup Mode (USP V and VM) When backup mode is chosen and a power failure occurs, storage system operations will continue normally for 200 milliseconds. If the power failure exceeds 200 ms, the storage system uses power from the batteries to back up the cache memory and shared memory for 36 hours or 48 hours, depending on the amount of cache memory.
  • Page 52: Software Solutions

    Software Solutions All current Sun StorageTek 9900 software products are supported on the new StorageTek 9985V providing a complete suite of storage management, data/information lifecycle management, and business continuity solutions. Complimenting the Sun StorageTek 9985V system is a set of specific software offerings providing storage resource management, performance tuning, and business continuity solutions.
  • Page 53: Storagetek 9900 Server Priority Manager

    Storage resources can be allocated based on business requirements and priorities and be re-assigned as needed. To the host, the partition appears as if it is its own storage system and can be managed as such. Administrators will have access to configure and manage resources within their assigned partitions. Overall system priorities, disk space and tiers of storage can be managed and used most efficiently based on business applications and requirements by allocating and adjusting resources to each partition.
  • Page 54: Storagetek 9900 Universal Replicator

    All current copy products will work within a StorageTek 9900 series environment. When used in conjunction with the StorageTek 9985V system, the Universal Replicator becomes the first storage-based replication software component that provides server-free and application-transparent journal-based multi-target replication features for data from heterogeneous storage environments.
  • Page 55: Storagetek 9900 Hicommand Data Link Manager

    StorageTek 9900 Business Continuity Suite Sun Microsystems has an industry-unique commitment to the paradigm of continuous business. Continuous business refers to an enterprise’s ability to minimize system downtime, whether it is planned or unplanned.
  • Page 56: Storagetek 9900 In-System Replication Suite

    Sun Microsystems adds business continuity solutions to ensure quick recovery from unplanned downtime resulting from acts of nature, human errors, application errors, and malicious attacks. StorageTek 9900 In-System Replication Suite The StorageTek 9900 In-System Replication includes both ShadowImage and Copy on Write. In-System Replication Suite along with the Sun StorageTek 9900 series, allows information to be protected and accessible 24x7.
  • Page 57 B e n e f i t B e n e f i t C o n t e n t s C o n t e n t s Q u i c k v o lu m e c r e a t i o n w / o f o r m a t t i n g o r p h y s i c a l i n s t a lla t i o n Q u i c k v o lu m e c r e a t i o n w / o f o r m a t t i n g o r p h y s i c a l i n s t a lla t i o n ( 1 ) ( 1 )
  • Page 58: Field Issues

    Field Issues Cluster Support Please refer to the following URL for Cluster Support of the ST9900 Family of Storage Systems. http://suncluster.eng/products/SC3.1/config/sc3ConfigurationGuide-6.htm#pgfId-780547 WWWW (What Works With What) There are several WWWW documents associated with the ST9900 family of products. Here is an explanation of the WWWW documents. Token #344150 (WWWW) This is the most important WWWW and it contains the following information: ...
  • Page 59: Features And Capabilities Of The Sun Storagetek 9985V

    (ELUN) requires no physical disk storage on the StorageTek 9985V. Multi-Vendor Host Platform Storage Pooling External LUN Mapping An external heterogeneous storage system can be connected to a StorageTek 9985V system (1) through a direct connection, (2) through a switch, or, remotely, through extenders.
  • Page 60: Storagetek 9985V Virtual Partitioning

    Machine. Storage Navigator provides administrator and user level authorities and maintains an access control directory to keep manage user authorities. This ensures that each defined Virtual Private Storage Machine within a StorageTek 9985V system is fully secure. Just the Facts October 2007 Sun Confidential –...
  • Page 61: Operating System Support

    Operating System Support The following operating systems are supported at the initial release of the Sun StorageTek 9985V: Note: These are listed as examples only. Do not configure you systems from this list. Go to SunWin token #344150 and 385413...
  • Page 62: Lun Mapping

    Storage Domains This feature lets the user carve the Sun StorageTek 9985V system into several storage domains (see Figure 2 below). Storage domains can be used to create multiple logical arrays and to assign volumes to these arrays.
  • Page 63: Encrypted Communications

    Encrypted Communications Only encrypted services are provided on the Sun StorageTek 9985V system — that is, the monitoring and diagnostic software as well as the management software support only through https encrypted communications. Just the Facts October 2007 Sun Confidential – For Internal Use and Authorized Partner Use Only...
  • Page 64: Reliability, Availability, And Serviceability (Ras)

    Reliability, Availability, and Serviceability (RAS) The ST9985V is not expected to fail in any way that would interrupt user access to data. The ST9985V can sustain multiple component failures and still continue to provide full access to all stored user data. Note: While access to user data is never compromised, the failure of a key component can degrade performance.
  • Page 65 (GBICs). All microcode upgrades can be performed during normal operations using the service processor (SVP) and the alternate path facilities of the host. Online microcode upgrades can be performed without interrupting open-system host operations. Error Reporting. The ST9985V reports service information messages (SIMs) to notify users of errors and service requirements.
  • Page 66: System Administration

    System Administration Please refer to the following web page for the latest User Guides and maintenance manuals: http://pts-storage.west/products/T99x0/documentation.html Just the Facts October 2007 Sun Confidential – For Internal Use and Authorized Partner Use Only...
  • Page 67: What Works With What

    What Works With What Please refer to the following web page for the latest compatibility information. This information changes on a regular basis and it is strongly recommended that this web site be reviewed rather than depending on the information in this “Just the Facts” document which may rapidly become out of date. 1) Pls.
  • Page 68: Compatible Software

    Compatible Software The following software is compatible with the Sun StorageTek 9985V system. Sun Software StorageTek Enterprise Backup Software (EBS) 7.,1 StorageTek QFS software 4.0, or later StorageTek SAM-FS software 4.0, or later Sun StorageTek Enterprise Storage Manager 2.1 software, or higher Sun StorageTek Enterprise Backup software (EBS) 7.1...
  • Page 69: Ordering Information

    Ordering Information "How do I get a quote?" In the Americas, please engage the Storage Center of Excellence (SCOE) by sending your request to scoe@Sun.com or by engaging your storage specialist NEW PARTS NOW AVAILABLE FOR SALE: =============================================================================== Options and Spares Order Number List Price Discount Category SunSpectrum(SM)Price*...
  • Page 70 required for the RAID configuration to be adopted. RAID5 (3D+1P)/RAID1 (2D+2D) - 4 sets of the option. RAID5 (7D+1P)/RAID1 (4D+4D) - 8 sets of the option. RAID6 (6D+2P) - 8 sets of the option. RoHS-5 compliant. TV9DKC-F615I-72K1 $1,995.00 $6.0 Description: Sun StorageTek(TM) 9985V 72G HDD Spare Canister consists of one 72G/15K HDD contained in a canister for installation as a spare into a ST9985V Disk Chassis (TV9DKC-F615i-B2).
  • Page 71 Sun StorageTek(TM) 9985V 8GB cache memory module expands the cache memory capacity by 8Gbytes. The option consists of four DIMM boards on which 1GB DRAMs are mounted. The maximum number of installable options is 8 sets (Cache capacity: 64GB). The required number of the options is determined based on the disk capacity of the subsystem..
  • Page 72 implementations requiring the highest level of management availability and additional battery (TV9DKC-F615i-LGAB) when cache memory capacity exceeds 80MB. This Chassis must be installed immediately above the TV9DKC615I-5. TV9DKC-F615I-SVP $5,795.00 Description: Sun StorageTek(TM) 9985V optional SVP (Service Processor) for high availability implementations. This is installed in the TV9DKC-F615I-SBX. When failure occurs in the primary SVP, the active SVP is automatically switched to the secondary SVP and the SVP continues its operation.
  • Page 73: Description: $5,795.00

    frame; capacity independent license; included with first license purchased for each disk controller frame. TV9044-220035-01 $1.00 M Description: Sun StorageTek(TM) 9985V Disaster Recovery Bundle Media Kit includes TC Sync, Universal Replicator 2DC and RAID Manager media kit, no license, product documentation on CDROM; included with first license purchased for each disk controller frame.
  • Page 74: Description: $3,495.00

    TV9044-220035-03G $2,655.00 Description: Sun StorageTek(TM) 9985V Disaster Recovery Bundle (Suite) includes TC Sync, Universal Replicator 2DC and RAID Manager, 501+TB License Tier, license key on CDROM, license certificate on paper; pricing based on usable capacity for each 1TB increment up to a total greater than 500TB per disk controller frame (Primary and secondary volumes on a system);...
  • Page 75: Description: $2,095.00

    Sun StorageTek(TM) 9985V Disaster Recovery Extended Bundle (Suite) includes Universal Replicator 3DC and 4x4, 101-500TB License Band, license key on CDROM, license certificate on paper; pricing based on usable capacity for each 1TB increment up to a total of 500TB per disk controller frame (Primary and secondary volumes on a system).
  • Page 76: Description: $2,095.00

    TV9044-220037-03F $2,855.00 Description: Sun StorageTek(TM) 9985V In-System Replication Bundle (Suite) includes ShadowImage and Copy-on-Write, 101-500TB License Band. License key on CDROM. License certificate on paper. Pricing based on usable capacity for each 1TB increment up to a total of 500TB per disk controller frame. All TB Qty ordered within destination band.
  • Page 77 in 10TB, 20TB, 50TB increments up to a total of 110TBs. TV9044-220039-03D $45,975.00 Description: Sun StorageTek(TM) 9985V Dynamic Provisioning Additional 50TB License Band. License key on CDROM. License certificate on paper. Pricing and license capacity based on total usable capacity of volumes in the HDP pool additional 50TB increment per disk controller frame.
  • Page 78 disk controller frame. Capacity independent license. Included with first license purchased for each disk controller frame. TV9044-220041-03A $2,855.00 Description: Sun StorageTek(TM) 9985V HiCommand Tiered Storage Manager Internal 1-5TB License Band. License key on CDROM. License certificate on paper. Pricing based on internal raw capacity for each 1TB increment up to a total of 5TB per disk controller frame.
  • Page 79 increments in the 41-80TB License Band. License key on CDROM. License certificate on paper. Pricing based on external usable capacity for each 4TB increment from 41-80TB per disk controller frame. All TB Qty ordered within destination band. TV9044-220042-03D $985.00 Description: Sun StorageTek(TM) 9985V HiCommand Tiered Storage Manager External 4TB increments in the 81-160TB License Band.
  • Page 80 increment up to a total of 25TB per disk controller frame. All TB Qty ordered within destination band. TV9044-220043-03D $7,555.00 Description: Sun StorageTek(TM) 9985V Compatible FlashCopy License. Includes ShadowImage 26-50TB License Band. License key on CDROM. License certificate on paper. Pricing based on usable capacity for each 1TB increment up to a total of 50TB per disk controller frame.
  • Page 81: License. Product Documentation On Cdrom. Included With First License

    capacity for each 1TB increment up to a total of 50TB per disk controller frame. All TB Qty ordered within destination band. TV9044-220044-03E $2,755.00 Description: Sun StorageTek(TM) 9985V Compatible PAV 51-100TB License Band. License key on CDROM. License certificate on paper. Pricing based on usable capacity for each 1TB increment up to a total of 100TB per disk controller frame.
  • Page 82 valid for 120 days;For ST9900 systems TV9044-220058-01 $1.00 M Description: Sun StorageTek(TM) 9900 HiCommand Device Manager 5.8 base kit, no license, media kit and documentation on CDROM; for Solaris 8 & 9, Windows NT 4.0 SP6a or later & Windows 2000 SP2 & SP3 & SP4; included with first license purchased for each disk controller frame;...
  • Page 83 TV9-220035-03-3ST $4,572.00 Description: Sun StorageTek(TM) 9985V Disaster Recovery Bundle (Suite) Base License for TC Sync, Universal Replicator 2DC and RAID Manager. Base License, one per disk controller frame, capacity independent license, included with first license purchased for each disk controller frame. 3 Year Standard Support TV9-220035-03A-1PR $1,572.00...
  • Page 84 usable capacity for each 1TB increment up to a total of 10TB per disk controller frame(Primary and secondary volumes on a system); All TB Qty ordered within destination band. 3 Year Standard Support TV9-220035-03C-1PR $1,140.00 Description: Sun StorageTek(TM) 9985V Disaster Recovery Bundle (Suite) includes TC Sync, Universal Replicator 2DC and RAID Manager, 11-25TB License Band, license key on CDROM, license certificate on paper;...
  • Page 85 Description: Sun StorageTek(TM) 9985V Disaster Recovery Bundle (Suite) includes TC Sync, Universal Replicator 2DC and RAID Manager, 51-100TB License Tier, license key on CDROM, license certificate on paper; pricing based on usable capacity for each 1TB increment up to a total of 100TB per disk controller frame (Primary and secondary volumes on a system);...
  • Page 86 usable capacity for each 1TB increment up to a total greater than 500TB per disk controller frame (Primary and secondary volumes on a system); All TB Qty ordered within destination band. Annual Premium Support TV9-220035-03G-1ST $456.00 Description: Sun StorageTek(TM) 9985V Disaster Recovery Bundle (Suite) includes TC Sync, Universal Replicator 2DC and RAID Manager, 501+TB License Tier, license key on CDROM, license certificate on paper;...
  • Page 87 Description: Sun StorageTek(TM) 9985V Disaster Recovery Extended Bundle (Suite) includes Universal Replicator 3DC and 4x4, 1-5TB License Band, license key on CDROM, license certificate on paper; pricing based on usable capacity for each 1TB increment up to a total of 5TB per disk controller frame (Primary and secondary volumes on a system).
  • Page 88 capacity for each 1TB increment up to a total of 25TB per disk controller frame (Primary and secondary volumes on a system). All TB Qty ordered within destination band. Annual Premium Support TV9-220036-03C-1ST $84.00 Description: Sun StorageTek(TM) 9985V Disaster Recovery Extended Bundle (Suite) includes Universal Replicator 3DC and 4x4, 11-25TB License Band, license key on CDROM, license certificate on paper;...
  • Page 89 Description: Sun StorageTek(TM) 9985V Disaster Recovery Extended Bundle (Suite) includes Universal Replicator 3DC and 4x4, 51-100TB License Band, license key on CDROM, license certificate on paper; pricing based on usable capacity for each 1TB increment up to a total of 100TB per disk controller frame (Primary and secondary volumes on a system).
  • Page 90 capacity for each 1TB increment up to a total greater than 500TB per disk controller frame (Primary and secondary volumes on a system). All TB Qty ordered within destination band. Annual Standard Support TV9-220036-03G-3PR $180.00 Description: Sun StorageTek(TM) 9985V Disaster Recovery Extended Bundle (Suite) includes Universal Replicator 3DC and 4x4, >500TB License Band, license key on CDROM, license certificate on paper;...
  • Page 91 Sun StorageTek(TM) 9985V In-System Replication Bundle (Suite) includes ShadowImage and Copy-on-Write, 1-5TB License Band. License key on CDROM. License certificate on paper. Pricing based on usable capacity for each 1TB increment up to a total of 5TB per disk controller frame. All TB Qty ordered within destination band.
  • Page 92 TV9-220037-03C-3ST $2,736.00 Description: Sun StorageTek(TM) 9985V In-System Replication Bundle (Suite) includes ShadowImage and Copy-on-Write, 11-25TB License Band. License key on CDROM. License certificate on paper. Pricing based on usable capacity for each 1TB increment up to a total of 25TB per disk controller frame. All TB Qty ordered within destination band.
  • Page 93 for each 1TB increment up to a total of 500TB per disk controller frame. All TB Qty ordered within destination band. Annual Premium Support TV9-220037-03F-1ST $480.00 Description: Sun StorageTek(TM) 9985V In-System Replication Bundle (Suite) includes ShadowImage and Copy-on-Write, 101-500TB License Band. License key on CDROM.
  • Page 94: Hdvm, Resource Mgr, Server Priority Mgr And Virtual Partitioning Mgr 4

    Description: Sun StorageTek(TM) 9985V Basic Operating System (BOS) Base License includes HdvM, Resource Mgr, Server Priority Mgr and Virtual Partitioning Mgr 4 partitions base license; one per disk controller frame; capacity independent license; included with first license purchased for each disk controller frame. Annual Premium Support TV9-220034-03-1ST $2,004.00 Description: Sun StorageTek(TM) 9985V Basic Operating System (BOS) Base License...
  • Page 95 Year Standard Support TV9-220038-3MED $180.00 Description: Sun StorageTek(TM) 9985V Basic Operating System Virtualization (BOS-E) Media Kit includes UVM, Virtual Partitioning Mgr 5+ partitions media kit, no license, product documentation on CDROM; included with first license purchased for each disk controller frame. 3 Year Additional Media TV9-220038-MEDIA $60.00 Description:...
  • Page 96 Band. License key on CDROM. License certificate on paper. Pricing and license capacity based on total usable capacity of volumes in the HDP pool additional 10TB increment per disk controller frame. TB Qty ordered in 10TB, 20TB, 50TB increments up to a total of 110TBs. Annual Premium Support TV9-220039-03B-1ST $2,232.00...
  • Page 97 Support TV9-220039-03D-1ST $7,812.00 Description: Sun StorageTek(TM) 9985V Dynamic Provisioning Additional 50TB License Band. License key on CDROM. License certificate on paper. Pricing and license capacity based on total usable capacity of volumes in the HDP pool additional 50TB increment per disk controller frame. TB Qty ordered in 10TB, 20TB, 50TB increments up to total of 110TBs.
  • Page 98 purchased for each disk controller frame. Annual Premium Support TV9-220040-03-1ST $768.00 Description: Sun StorageTek(TM) 9985V HiCommand Tuning Manager Base License. License key on CDROM. License certificate on paper. One per disk controller frame. Capacity independent license. Included with first license purchased for each disk controller frame.
  • Page 99 TV9-220040-03B-3ST $1,476.00 Description: Sun StorageTek(TM) 9985V HiCommand Tuning Manager 6-10TB License Band. License key on CDROM. License certificate on paper. Pricing based on internal raw capacity for each 1TB increment up to a total of 10TB per disk controller frame. All TB Qty ordered within destination band. 3 Year Standard Support TV9-220040-03C-1PR $528.00...
  • Page 100 disk controller frame. All TB Qty ordered within destination band. Annual Premium Support TV9-220040-03E-1ST $264.00 Description: Sun StorageTek(TM) 9985V HiCommand Tuning Manager 51-100TB License Band. License key on CDROM. License certificate on paper. Pricing based on internal raw capacity for each 1TB increment up to a total of 100TB per disk controller frame.
  • Page 101 License key on CDROM. License certificate on paper. Pricing based on internal raw capacity for each 1TB increment up to a total greater than 500TB per disk controller frame. All TB Qty ordered within destination band. 3 Year Premium Support TV9-220040-03G-3ST $324.00 Description:...
  • Page 102 Sun StorageTek(TM) 9985V HiCommand Tiered Storage Manager Internal 1-5TB License Band. License key on CDROM. License certificate on paper. Pricing based on internal raw capacity for each 1TB increment up to a total of 5TB per disk controller frame. All TB Qty ordered within destination band.
  • Page 103 TV9-220041-03D-1ST $300.00 Description: Sun StorageTek(TM) 9985V HiCommand Tiered Storage Manager Internal 26-50TB License Band. License key on CDROM. License certificate on paper. Pricing based on internal raw capacity for each 1TB increment up to a total of 50TB per disk controller frame. All TB Qty ordered within destination band.
  • Page 104 to a total of 500TB per disk controller frame. All TB Qty ordered within destination band.. 3 Year Premium Support TV9-220041-03F-3ST $432.00 Description: Sun StorageTek(TM) 9985V HiCommand Tiered Storage Manager Internal 101-500TB License Band. License key on CDROM. License certificate on paper.
  • Page 105 increments in the 21-40TB License Band. License key on CDROM. License certificate on paper. Pricing based on external usable capacity for each 4TB increment from 21-40TB per disk controller frame. All TB Qty ordered within destination band. Annual Premium Support TV9-220042-03B-1ST $264.00 Description:...
  • Page 106 Description: Sun StorageTek(TM) 9985V HiCommand Tiered Storage Manager External 4TB increments in the 81-160TB License Band. License key on CDROM. License certificate on paper. Pricing based on external usable capacity for each 4TB increment from 81-160TB per disk controller frame. All TB Qty ordered within destination band.
  • Page 107 ordered within destination band. 3 Year Standard Support TV9-220042-03G-1PR $96.00 Description: Sun StorageTek(TM) 9985V HiCommand Tiered Storage Manager External 4TB increments in the >1000TB License Band. License key on CDROM. License certificate on paper. Pricing based on external usable capacity for each 4TB increment greater than 1000TB per disk controller frame.
  • Page 108 Year Standard Support TV9-220043-03A-1PR $2,748.00 Description: Sun StorageTek(TM) 9985V Compatible FlashCopy License. Includes ShadowImage 1-5TB License Band. License key on CDROM. License certificate on paper. Pricing based on usable capacity for each 1TB increment up to a total of 5TB per disk controller frame. All TB Qty ordered within destination band.
  • Page 109 certificate on paper. Pricing based on usable capacity for each 1TB increment up to a total of 25TB per disk controller frame. All TB Qty ordered within destination band. Annual Standard Support TV9-220043-03C-3PR $5,292.00 Description: Sun StorageTek(TM) 9985V Compatible FlashCopy License. Includes ShadowImage 11-25TB License Band.
  • Page 110 Sun StorageTek(TM) 9985V CompatibleFlashCopy License. Includes ShadowImage 51-100TB License Band. License key on CDROM. License certificate on paper. Pricing based on usable capacity for each 1TB increment up to a total of 100TB per disk controller frame. All TB Qty ordered within destination band.
  • Page 111 Description: Sun StorageTek(TM) 9985V Compatible FlashCopy Media Kit includes ShadowImage media kit. No license. Product documentation on CDROM. Included with first license purchased for each disk controller frame. Additional Media TV9-220044-03-1PR $1,752.00 Description: Sun StorageTek(TM) 9985V Compatible PAV Base License. License key on CDROM.
  • Page 112 on CDROM. License certificate on paper. Pricing based on usable capacity for each 1TB increment up to a total of 10TB per disk controller frame. All TB Qty ordered within destination band. 3 Year Premium Support TV9-220044-03B-3ST $2,736.00 Description: Sun StorageTek(TM) 9985V Compatible PAV 6-10TB License Band. License key on CDROM.
  • Page 113 key on CDROM. License certificate on paper. Pricing based on usable capacity for each 1TB increment up to a total of 100TB per disk controller frame. All TB Qty ordered within destination band. Annual Premium Support TV9-220044-03E-1ST $468.00 Description: Sun StorageTek(TM) 9985V Compatible PAV 51-100TB License Band. License key on CDROM.
  • Page 114 Description: Sun StorageTek(TM) 9985V Compatible PAV >500TB License Band. License key on CDROM. License certificate on paper. Pricing based on usable capacity for each 1TB increment up to a total greater than 500TB per disk controller frame. All TB Qty ordered within destination band. 3 Year Premium Support TV9-220044-03G-3ST $792.00...
  • Page 115 (Prerequisite: Sun StorageTek 9900 Resource Manager and SANtinel software; for Sun StorageTek 9900 systems. Additional Media W9D-T13-1DSK-1P $84.00 Description: Sun StorageTek 9985V System disk drive Upgrade to 1 Year of Platinum Support. W9D-T13-1DSK-24-1G $60.00 Description: Sun StorageTek 9985V System disk drive Upgrade to Gold Support + 7X24...
  • Page 116 Description: Sun StorageTek 9985V System Upgrade to 3 Years of Platinum Support. Professional Services Order Number List Price Discount Category SunSpectrum(SM)Price* Note P-WW-PS-ED85VBOS-C $999,999.00 C Description: FOR RESELL/CO-DELIVER, IDO PARTNER PURCHASE ONLY: Sun Professional Services High End Disk Integration Service for ST9985V Basic Operating...
  • Page 117 Description: BOS Virtual for ST9985V can be included as an addition to the Base (BOS) configuration with additional Virtual Partition Manager support for more than 4 Virtual Partitions, service also includes support for Universal Volume Manager based on UVM Licensed TB's WW-PS-ED85BOSV-C $999,999.00 C Description:...
  • Page 118 ST9985V Basic Operating System (BOS) Mainframe configuration Includes Device Manager, Resource Manager, and Virtual Partition Manager support for up to 4 virtual Partitions. Large Configuration- Up to 120 TB of Disk, Up to 16 LPARs included. WW-PS-M85VBOS-M $78,000.00 Description: ST9985V Basic Operating System (BOS) configuration Includes Device Manager, Resource Manager, and Virtual Partition Manager support for up to 4 virtual Partitions.Medium Configuration- Up to 70 TB of Disk, Up to 8 LPARs included.
  • Page 119 Copyright 2005-2007 Sun Microsystems, Inc. All Rights Reserved. Sun, Sun Microsystems, the Sun Logo, and SunSpectrum are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the United States and other countries. Just the Facts October 2007 Sun Confidential – For Internal Use and Authorized Partner Use Only...
  • Page 120 All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the United States and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. Q1FY2008-232I Oct 09, 2007 SUN HARDWARE PRODUCT INTRO: Announcing Sun StorageTek(TM) 9985V System This section contains information for Sun partners.
  • Page 121: Section 1. How Products Are Licensed On The St9985V

    All Rights Reserved. Sun, Sun Microsystems, the Sun Logo, and SunSpectrum are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the United States and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc.
  • Page 122 1. Features which are licensed based on ST9985V by Internal Capacity Only. Suite - pricing based on Internal Raw capacity for each 1TB increments Basic Operating System (BOS) 1.1. 1.2.HiCommand Tuning Manager – pricing based on internal raw capacity for each 1TB increments –...
  • Page 123: Section 2. Licensing In Context Of St9985V Vs The St9985

    Protection Manager - pricing based on Total managed Primary Volumes (P-VOLs) and secondary volumes being protected by the Protection Manager Server for each 1TB increments up to 63TBs and in 4 increments up to unlimited capacity. 5. Features which are server based Dynamic Link Manager(SDLM) pricing per individual server up to a unlimited number of servers HiCommand Global Link Availability Manager(GLAM) - pricing based on 10 server Blocks Section 2.
  • Page 124: Frequently Asked Questions

    Competitive Comparison For competitive information, please visit the following URL: http://wikihome.sfbay.sun.com/Storage-Intelligence/Wiki.jsp?page=Disk#section-Disk- DatacenterDiskCompetition Frequently Asked Questions Q. How many models of the ST9985V are there? Are there separate "Pricing Reference Points" like there was on the ST9985? A. There is only one model of the ST9985V Unlike the ST9985, the ST9985V is available in one model only and there are no "Pricing Reference Points".
  • Page 125 clarification, the terms "ACP" and "DKA" are synonymous. Q. What is "Control Cache"? A. "Shared memory" is now known as "Control Cache". Q. Will the 100% Data Availability Guarantee be available with the ST9985V? A. Yes, the 100% Data Availability Guarantee will again be available for the ST9985V as it has been for the last 3 generations of ST9900 product.
  • Page 126 Q. How many ports are dedicated to internal storage? A. 16 ports are dedicated to internal storage. Q. How many ports are available in the Sun StorageTek 9985V Fibre Channel 8-Port and Sun StorageTek 9985V Fibre Channel 16-Port Front End Directors? A.
  • Page 127 The with the BOS V Virtual Partitions are expanded - up to 8 storage and 8 cache partitions. Q. Is installation included in the price of Sun StorageTek 9985V System? A. ST9985V product purchase includes Sun StorageTek(SM) 9985V Installation Service, (9985V Installation) a basic install offering, for new system (minimum 1 controller unit) purchase.
  • Page 128 5. Reduced Power and Cooling requirements due to fewer physical disks required. The Sun StorageTek 9985V and 9990V are the first and only enterprise storage systems to support both virtualization and thin provisioning. ST9900 Dynamic Provisioning software is not unique in the industry, but at this moment in time neither EMC, nor IBM has delivered a thin provisioning solution.
  • Page 129 A. Like any other new software, features and enhancements will be delivered in a phased release over time. The initial release of Dynamic Provisioning software contains the basic function required to allow customers to begin using and testing it so that they can get familiar with its behavior and benefits.
  • Page 130 ST9900 Remote Replication Synchronous Software and ST9900 Universal Replicator Software for both Open Systems and Z/OS mainframes. * ST9900 Disaster Recovery Extended Software - Customer must have ST9900 Disaster Recovery Software installed as a pre-requisite. It consists of ST9900 Universal Replicator with advanced function which includes the 3 Datacenter capabilities for both Open Systems and z/OS mainframes and the 4x4 function for z/OS mainframes only.
  • Page 131 A. Sun Data Systems storage management software benefits are based upon one common management software interface. Rather than provide end-users with disparate interfaces for disparate platforms, essentially resulting in multiple islands of storage, Sun provides customers with the same software, the same management interfaces, and the same key tools to manage all of ST9900 storage systems from a single console.
  • Page 132 513698 ? Sun StorageTek 9985V Technical Presentation 510459 ? Dynamic Provisioning Data Sheet 513640 ? Sun StorageTek 9985V Data Sheet 513696 ? Sun StorageTek 9985V Just The Facts 513697 ? Sun StorageTek 9985V Customer Presentation 385413 ? What works with what 385413 ? Feature Availability Report Q.
  • Page 133 A. First of all, the ST 9985V does not have an embedded switch like a Brocade on the back end. The back end is still predominately based on Fibre-Channel Arbitrated Loop. However, there are some significant/subtle changes that those of your who are more technically inclined may be interested in.
  • Page 134 Q. Does the ST9985V have any data encryption methodology? A. There is no in-system methodology for encrypting data on disk. Please stay tuned for forthcoming information on qualified encryption appliances. Q. Can different data cache densities be intermixed on the ST9985V? A.
  • Page 135 CY2007. With external storage support Dynamic Provisioning with complement Sun's ST9900 virtualization strategy by providing both aggregation and thin provisioning for the whole virtual storage environment that includes both internal and external storage. Q. Are there expected changes to the Services ordering numbers in near future? A.
  • Page 136: Support Services

    Support Services Sun StorageTek Service Support Offerings The Sun StorageTek Service program is an innovative and flexible service offering that allows customers to choose the level of service best suited to their needs, ranging from mission-critical support for maximum solution availability to backup assistance for self-support customers. The Sun StorageTek Service program provides a simple pricing structure in which a single fee covers support for an entire system, including related hardware and peripherals, the Solaris Operating Environment software, and telephone support for Sun...
  • Page 137: Sun Software Premium Support(Pr)

    Series products, have standalone product support information (warranty, W9D parts and pricing, installation policy, Sun StorageTek Service pricing, etc.) that are unique to each of these products. The official Sun StorageTek 9985V warranty statements are maintained at Sun's external web site at www.sun.com/service/support/warranty...
  • Page 138 *average response times. All Sun StorageTek 9900 Series hardware components, disk groups, disk spares, port interface boards, disk frames, etc., receive the remaining warranty term of the ST9990 controller unit to which they are attached. The maximum warranty period of any given controller unit is 3 years.
  • Page 139: Installation Information

    Extra charge required. Order EIS- purchase 9900-4DISKE-AH StorageTek 9985V product includes Sun StorageTek (SM) 9900 Installation Service, (9900 Installation) a basic install offering, for new subsystem (minimum 1 control unit) purchases. This installation is provided during normal business hours. 9900 Installation currently includes the high-level deliverables shown below. The...
  • Page 140 Review packing list Install and configure HBA's in Sun servers Install Solaris patches, if applicable. Connect controllers, disk frames and StorageTek 9985V components Connect subsystem to host server(s) Power up and verify functionality (diagnostic level.) Install remote console components into customer-supplied workstation Connect service processor to customer phone line.
  • Page 141: Questions And Answers

    Questions and Answers Q. What is Sun Support Services policy on third-party servers connected to StorageTek 9900 Series products? A. StorageTek 9900 Series products are designed for attachment to Sun Solaris and other open systems (HP- UX, IBM AIX), non-UNIX (i.e. Linux,Windows) and mainframe server platforms. The details of these supported configurations are provided in the WWWW matrix.
  • Page 142 configurations via Sun Storage Technical Service Centers. These centers also provide a means to coordinate the receipt and problem resolution as part of Sun Remote Services for proactive, and preventive support. Sun Support Services provides Sun StorageTek customers with exclusive access to the Sun StorageTek Joint Support Center.
  • Page 143 Internal Only Questions & Answers Q. What documents should I use to understand interoperability between the ST9985V, servers, operating systems, switches, switch firmware, clustering, multipathing, and TrueCopy? A. Please refer to the documents described below, as well as the URL where you can go find them.
  • Page 144 and back-end storage adapters. Unlike current ST9985 that has 4Gb/s front-end (adapters), but only 2Gb/s back-end (to disks). The maximum internal bandwidth was increased from 12GB/s on the ST9985 to 13.3 GB/s on the ST9985V Q. This product update doesn't include consolidation allowances. Where do I obtain values for the storage systems that I want to consolidate onto the ST9985V?
  • Page 145 management, data protection and disaster recovery. Although the ST9985V can provide a platform for building solutions across virtually all vertical markets, the Financial Services, Telecom, Utilities, Transportation, Healthcare, Federal, State and Local Governments and Pharmaceutical industries provide especially good targets because of their storage growth and need for high performance, high availability storage solutions.
  • Page 146: Sun Educational Services

    A. For customers running multiple applications with varying requirements, the ST9985V's unique ability to host tiered storage and enable logical partitioning reduces investment and operational costs by providing tiered storage within a single, centrally managed system. ST9900 Tiered Storage manager software allows the customer to dynamically and non-disruptively move their application data to the right platform as the value or the processing characteristics of the data changes over time.
  • Page 147 Customer Administration  and  Configuration  (Customer   class) HDS­ 4 20 Increased  to 3 day  ILT.   New   course  number   tbd. Services Support Training Course  IESHDS­ 4 51 Increased  to 5 day  SE   training  (Replaces IESHDS­ 4 20).   Available   11/30/07.   Course:   WH­ 1 513  WBT:   ST9985  to ST9985V  Differences  (for  trained  Support   Engineers)   Avail.
  • Page 148 ======================================================================= Field Enablement Sales Awareness Storage Weekly Call Webinar: ?Sales and Technical Differences webinar? on ST9985 and ST9985V, ST9990 and ST990V Avail 10/2/07. http://mysales.central.sun.com/public/storage/events_and_activities/storage_confe rence_calls/ Newsletter: Sun Storage Newsletter ST9985V http://mysales.central.sun.com/public/storage/events_and_activities/storage_confe rence_calls/#newsletter Sun Learning Services (SLS) http://mylearning.central.sun.com/ Sales, Pre-sales Technical, and Channel Training (Course # tbd) Sun StorageTek 9900 Series Sales Fundamentals and Introducing the 9985V (Course # tbd) ST9985 and ST9900 Technical Fundamentals and...
  • Page 149: Sun Professional Services

    Additional Pre-Sales Technical Training Device Manager Technical Webinar ? 1.5 hour webcast. Available 7/11/07. Dynamic Provisioning Technical Webinar ? 1.5 hour webcast. Available 7/12/07. Sun StorageTek 9900 Series Network Storage Controller Architecture and Administration ? 5 day classroom/lab Available 7/12/07. Register at sun.com/training ================================= Sun Learning Services will send out regular email communications...
  • Page 150 3) or a combination of any of the above components from #1 and #2 above, for example a Medium TCS component with and XLG UR component depending on the customer's requirements. Disaster Recovery Extended Service- Service is a Custom engagement and is built on a combination of Sync TrueCopy (TC Sync) and Universal Replicator (UR) Software Advanced Features components.
  • Page 151: Planning For Installation And Operation

    Installation Planning for Installation and Operation Go here: http://pts-storage.west/products/T99x0/documentation.html Please refer to the following document: Universal Storage Platform VM Installation Planning Guide (MK-97RD6079) Installation Requirements This chapter provides the installation requirements for the Universal Storage Platform VM storage system. Safety Requirements Delivery Requirements Storage Requirements Facilities Requirements...
  • Page 152 Safety Requirements The safety requirements for Universal Storage Platform VM installation are: Safety regulations: The data center must comply with all applicable safety regulations, standards, and requirements. Fire protection: The data center must have an operational fire protection system. Hazards: The data center must be free of hazards (e.g., cables on the floor that obstruct access).
  • Page 153 Delivery Requirements The customer site must accommodate the delivery and movement of the equipment to the installation location in the data center. The delivery requirements for Universal Storage Platform VM installation are: Dimensions: The loading bay, hallways, doors, elevators, and stairs must be large enough to allow the delivered equipment to be moved to the installation location.
  • Page 154 Storage Requirements If the delivered equipment needs to be stored after delivery and prior to installation, the storage location must meet the environmental requirements for the Universal Storage Platform VM (see Table 2-2). Table 2-2 Environmental Specifications for Storage Shipping  &  Storage* Parameter High Temperature  °F (°C)
  • Page 155 Facilities Requirements The customer site must meet the following facilities requirements: General: The data center must be fully operational (e.g., power, air conditioning, cabling, fire protection system). Floor: The data center must have a tiled raised floor. ESD: The data center must provide adequate protection from electrostatic discharge (ESD). Electrical interference: The data center must provide adequate protection from electrical/radio frequency interference.
  • Page 156 Physical Specifications and Requirements Figure 2-1 shows a physical overview of the Universal Storage Platform VM. The physical specifications and requirements for the USP VM include: Dimensions and Weight Service Clearance, Floor Cutout, and Floor Load Rating     Primary Rack Secondary Rack Disk Chassis (DKU-R1)
  • Page 157 Dimensions and Weight Figure 2-2 shows the dimensions of the single-rack configuration. Figure 2-3 shows the dimensions of the twin-rack configuration. Table 2-3 lists the dimension and weight specifications for the Universal Storage Platform VM components. TOP VIEW 1046 mm 601 mm REAR VIEW FRONT VIEW...
  • Page 158   TOP VIEW 1046 mm 601 mm  601 mm  TBD  FRONT VIEW 2001 mm  Figure 2-3 Physical Dimensions: Twin-Rack Configuration Just the Facts October 2007 Sun Confidential – For Internal Use and Authorized Partner Use Only...
  • Page 159 Table 2-3 Component Specifications: Weight and Dimension Dimension  (mm) Model   Number Weight   (kg) Width Depth Height DKC615I­ 5 DKC­ F 615I­ B 2 80.5 DKC­ F 615I­ S BX DKC­ F 615I­ L GAB — — — DKC­ F 615I­ P LUC —...
  • Page 160 Service Clearance, Floor Cutout, and Floor Load Rating This section specifies the service clearance requirements (a + b) for the Universal Storage Platform VM storage system, based on the floor load rating and the clearance (c), and the required floor cutouts for cabling.
  • Page 161: Service Clearance

    (Unit : mm) a *1 B *1 Rear 1100 65 125 1050 3250 DKC615 1050.00 200 or more 1100 Front 61.5 c *1 Front Floor cutout area for cables Screw jack DKC615 Caster Service clearance Grid panel (over 450mm x 450mm) Figure 2-4 Service Clearance and Floor Cutouts: Single Rack Notes:...
  • Page 162 (Unit: mm) 1220   Rear 1100 125 65 3250 835 655 655 835 1050 DKC515 1050 200 or more 1100 Front 61.5 61.5 c *1 Floor cutout area for cables DKC615 DKC615 Screw jack Caster Service clearance Grid panel (over 450mm x 450mm) G ...
  • Page 163: Breaker Configurations

    Power Specifications and Requirements This section describes the power specifications and requirements for the Universal Storage Platform VM storage system: Power Specifications and Power Supplies Breaker Configurations Power Connection Input Voltage and Input Frequency Circuit Breakers and Plugs Power Specifications and Power Supplies Table 2-6 lists the power specifications for the Universal Storage Platform VM, including inrush current, leakage current, input current, and steady current.
  • Page 164   Primary Rack Secondary Rack DKU-R1 DKU PS ×15 PS30 PS31 ×15 PS20 PS21 ×15 PS10 PS11 ×15 PS00 PS01 DKU PS DKU-R0  PS30 ×15 PS31 DKU-R3 PS20 ×15 PS21 ×15 PS30 PS31 ×15 PS10 PS11 ×15 PS20 PS21 PS00 ×15 PS01 ×15...
  • Page 165 Breaker Configurations For both racks, AC power is supplied to each power distribution unit (PDU) from the breaker. Figure 2-7 and Figure 2-8 show the breaker configurations for the primary and secondary racks, respectively.   DKU-R1          ...
  • Page 166 Power Connection The AC power input for the Universal Storage Platform VM has a duplex PDU structure. This duplex structure enables the entire rack to remain powered on in the event that power is removed from one of the two power distribution panels (PDPs). Direct connection to power.
  • Page 167   Primary Rack Secondary Rack PDP2 DKU-R1 UPS1           (1/20A) (1/20A) UPS2 DKU-R0 (1/20A)   DKU-R3         (1/20A) (1/20A)   (1/20A) DKU-R2 Branch Distribution Box To UPS To PDP To PDP To UPS PDP1 AC Input Line For the AC input power, connect one of the duplexes PDUs to the UPS...
  • Page 168 Input Voltage and Input Frequency Table 2-7 lists the input voltage and input frequency requirements for the Universal Storage Platform Table 2-7 Input Voltage and Input Frequency Requirements Frequency Input   Voltages  (AC) Conditions Tolerance(%) 60Hz  ±2H z 200V,   208V  or 230V 1 Phase +6% or ­8% 2 Wire  + Ground...
  • Page 169 Environmental Specifications and Requirements The environmental specifications and requirements for the Universal Storage Platform VM include: Temperature, Humidity, and Altitude Heat Output, Power Consumption, and Air Flow Loudness Vibration and Shock Temperature, Humidity, and Altitude Table 2-2 specifies the temperature, humidity, and altitude requirements for the Universal Storage Platform VM.
  • Page 170 Heat Output, Power Consumption, and Air Flow Table 2-9 lists the power consumption and heat output specifications and the air flow requirements for the Universal Storage Platform VM. These data generally apply to both 60-Hz and 50-Hz storage systems. The Universal Storage Platform VM requires less power and puts out less heat than the Hitachi TagmaStore ®...
  • Page 171 Table 2-10 Vibration and Shock Tolerances Condition Parameter Operating Non­ O perating Shipping  or  Storage Vibration 5­10 Hz:   0.25  mm   5­10 Hz:   2.5 mm Sine  Vibration:  *2   10­300 Hz: 0.49  m/s 10­70 Hz:   4.9m/s 4.9 m/s , 5 min. 70­99 Hz:   0.05  mm At  the  resonant  ...
  • Page 172: External Storage

    Operational Requirements The operational requirements for the Universal Storage Platform VM include: LAN connection (or RJ-11 analog phone line) for Hi-Track ® The Hi-Track maintenance support tool monitors the operation of the Universal Storage Platform VM, collects hardware status and error data, and transmits this data via LAN (or modem) to the Hitachi Data Systems Support Center.
  • Page 173 Table A-1 provides conversions for metric and standard (U.S.) units of measure associated with the Hitachi Universal Storage Platform VM storage system. For information on physical and logical storage capacity values on the USP VM storage system, see Convention for Storage Capacity Values.
  • Page 174 Just the Facts October 2007 Sun Confidential – For Internal Use and Authorized Partner Use Only...
  • Page 175 Just the Facts October 2007 Sun Confidential – For Internal Use and Authorized Partner Use Only...
  • Page 176 Just the Facts October 2007 Sun Confidential – For Internal Use and Authorized Partner Use Only...
  • Page 177: Glossary

    Glossary Term Definition Storage system consisting of trays and controller units. Storage system Array consisting of a minimum of one controller unit. Also includes one or more slots to house disks drives. Disk that serves as a hot-spare within an array. A reserve disk that can be made Array hot-spare available to all virtual disks within an array.
  • Page 178 Term Definition Disk Slot Slots on trays that house physical disks. VERITAS dynamic multi-pathing. Drive depopulation Drive depopulation allows additional spindles to be added to drive trays that are not fully populated with 14 drives. Cache mirroring with duplicate data paths to and from the cache. See mirrored Duplexed cache cache.
  • Page 179 Term Definition Host ports DSP ports attached to hosts or host-facing SAN ports. Any DSP port is capable of being either a host port or a storage port. Disk used by a controller unit to replace a failed disk. Hot-spare A hot-swappable component can be installed or removed by simply pulling the Hot-swappable component out and putting the new one in.
  • Page 180 Term Definition NL_Port A port attached to a node for use in all three topologies (point-to-point, arbitrated loop, or fabric). Network terminal concentrator — see above. A non-volatile (battery-backed) random access memory area used as an NVRAM cache intermediate store for data between a host computer system and disk drives to achieve faster writes and, in some cases, faster reads.
  • Page 181 Term Definition Reliability, availability, and serviceability. Reliability is a measure of the likelihood that problems will occur. A highly reliable system has few problems. Once a problem occurs, availability is the measure of how the system protects the user from being adversely affected by the problem. Serviceability is a measure of how easy it is to repair the problem.
  • Page 182 Term Definition Striping Laying data out over a series of disks or virtual disks, allows multiple disk controllers to simultaneously access data, thus improving performance. Total amount of data in a disk stripe, that is, the block size multiplied by number Stripe size of data disks in the stripe.
  • Page 183: Collateral

    While there are many user guides, the following is one of the most important. It provides a broad overview of the product rather than being a "point releases" about an individual feature. Sun StorageTek 9985V User Guide WEB INFORMATION: Internal http://onestop/storage/9900/index.shtml?menu...
  • Page 184: Contacts

    Contacts -Product Specialist, Brian Whitehouse x25968/954-351-4968 brian.whitehouse@sun.com -ST9900 Product Boss, Ken Ow-Wing x69248 ken.ow-wing@sun.com -ST9900 Product Manager, Susheel Chawla x74810 susheel.chawla@sun.com -ST9900 Business Lead, Graham Wilson x69250 graham.wilson@sun.com -SS Product Marketing, Chris Choi x49634/650-352-8460 chris.choi@sun.com -Services Product Marketing, Edmund Delsol x57867 edmund.delsol@sun.com -Global Storage Sales, Joan Prebish x74415 joan.prebish@sun.com -ES Product Marketing, Li Elliott x51972/ 303-225-7560 aili.elliott@sun.com -Sun Service Rep, Brian Sutcliffe x21377 brian.sutcliffe@sun.com...

Table of Contents