From the rear of the system:
I
1. Seat the system expander boards and the centerplane support board into the Sun
Fireplane interconnect assembly.
2. Install all slot 0 and slot 1 boards.
See the Component Serial Number Worksheet,
13.6
Powering On the System After the Sun
Fireplane Interconnect Installation
1. Connect the AC power cords to the 4 kW dual
2. Connect all I/O cables referencing the cable label for proper identification.
3. Power on the AC0 and AC1 circuit breakers for all power supplies in the system.
4. Close the Sun Fire E25K/E20K system cabinet access doors.
5. Once the main SC is booted and SMS is running, start the domain(s) by typing:
sc% setkeyswitch -d domain_id
where domain_id is the domain letter A-R.
6. Verify all required components are on by typing:
sc% showboards -v
7. Execute one
command for each domain to be started.
setkeyswitch
Chapter 13 Sun Fireplane Interconnect Replacement Procedure
, used to verify board position.
TABLE 13-1