Figure 9-2 Pci Cassette Removal - Sun Microsystems Sun Fire E25K Service Manual

Hide thumbs Also See for Sun Fire E25K:
Table of Contents

Advertisement

5. Label and remove the I/O cables from the cassette.
6. Press down the ejector latch at the top front of the cassette to release the ejector
handle (
FIGURE 9-2
7. Grab the handle and pull forward to release the cassette from the hsPCI+.
9.2.1.2
Installing the PCI Cassette
1. Insert the PCI cassette into the appropriate slot (C5V0, C3V0, C3V1, or C3V2).
2. Push the cassette inward and push the eject handle upward into position seating
the cassette into the connector.
3. Reconnect the I/O cables to the cassette.
4. To power on the board, the customer domain administrator should type:
sc% rcfgadm -d domain_id -c configure ap_id
where ap_id is a DR attachment point identifier for the PCI cassette. Refer to the
rcfgadm man page for attachment point identifier details.
5. Verify that the activation LED is green.
6. Close the Sun Fire E25K/E20K system cabinet access doors.
) and carefully remove the cassette.
FIGURE 9-2
PCI Cassette Removal
EMI cap
Ejector handle
Ejector latch
Cassette at C3V2
Chapter 9 I/O (Slot 1) Assemblies
9-9