1-5 Applicable Standards

EC Directives

EC Directive
Low Voltage
Directive
EMC
Directive
Note To conform to the EMC Directives, the Servomotor and Servo Drive must be installed under
the conditions described in 4-3 Wiring Conforming to EMC Directives.

UL/CSA Standards

Standard
UL Standard
CSA standard
The Servo Drives and Servomotors comply with UL 508C (file No. E179149) as long as the following
installation conditions 1 and 2 are met.
1. The Servo Drive must be used in a pollution degree 1 or 2 environment as defined in IEC 60664-
1 (example: installation in an IP54 control panel).
2. A UL-listed (with
between the power supply and noise filter.
Refer to the following table for the rated current of the circuit breaker or fuse.
You must use copper wiring with a temperature rating of 60°C or higher.
Korean Radio Regulations (KC)
· SMARTSTEP2-series Servo Drives comply with the Korean Radio Regulations (KC).
· The G-series Servomotors do not comply with the Korean Radio Regulations (KC).
Product

Applicable standards

AC Servo Drive
EN 61800-5-1
AC Servomotor
IEC 60034-1
AC Servo Drive
EN 55011 class A
group1
EN 61000-6-2
Product
Applicable standards
AC Servo Drive
AC Servomotor
AC Servo Drive
CSA C22.2 No. 14
AC Servomotor
CSA C22.2 No. 100
mark) circuit breaker or UL-listed (with
Servo Drive model
R7D-BPA5L
R7D-BP01L
R7D-BP02L
R7D-BP01H
R7D-BP02H
R7D-BP02HH
R7D-BP04H
1-5 Applicable Standards
Comments
Safety requirements for electronic equipment for mea-
surement, control, or laboratory use
Rotating electric machines
Radio disturbance limits and measurement methods of
industrial, scientific, and medical radio-frequency
equipment
Electromagnetic compatibility (EMC): Immunity stan-
dard for industrial environments
File number
UL 508C
E179149
UL1004-1
E331224
E179149
E331224
mark) fuse must be connected
Rated current of circuit breaker (A)
5
5
5
5
5
5
10