Connection Example 3: Connecting to SYSMAC CS1W-NC133/233/433 Position
Control Units
CS1W-NC133/233/433
Contents
5-VDC power supply (for pulse output)
5-V GND (for pulse output)
CW (output (+))
CW (output (−))
CCW (output (+))
CCW (output (−))
X-axis dev. cntr. reset output
X-axis origin input (24 V)
X-axis origin common
X-axis positioning complete input
24-V power supply for outputs
0-V power supply for output
X-axis input common
X-axis external interrupt input
X-axis origin proximity input
X-axis CCW limit input
X-axis CW limit input
X-axis emerg. stop input
App
Appendix-3
3-phase 200/240 VAC 50/60 Hz
R7A-CPB@S
No.
A4
5 VDC
A3
A5
A6
A7
A8
A10
A15
A14
A12
A1
A2
A24
24 VDC
A19
A21
A23
A22
A20
24 VDC
Incorrect signal wiring can cause damage to Units and the Servo Drive.
Precautions
Leave unused signal lines open and do not wire them.
for Correct Use
Use mode 2 for origin search.
Use the 5-VDC power supply for the command pulse inputs as a dedicated
power supply.
Do not share the power supply for brakes (24 VDC) with the 24-VDC power
supply for controls.
Recommended surge absorption diode: RU2 (Sanken Electric) or the
equivalent
Main circuit
power supply
OFF
NFB
R
X1
S
T
R7D-BP@
CN1
22
+CW
−CW
23
24
+CCW
−CCW
25
4
ECRST
14
GND
21
Z
10
INP
1
+24VIN
X1
2
RUN
13
0GND
9
/ALM
X1
11
BKIR
XB
26
FG
Main circuit contactor
ON
MC1
SUP
Surge suppressor
MC1
X1
PL
Servo error display
Reactor
CNA
L1
L2
L3
MC1
Connect External Regeneration
P
B1
Resistor when required.
R88M-G
Servomotor Power
CNB
Red
Cable
U
@
R7A-CAB
S
White
V
Blue
W
Green/
Yellow
Encoder Cable
CN2
R88A-CRGB@C
Brake Cable
R88A-CAGA@B
XB
24 VDC
@
M
E
B