Table 1 :Parameter Adjustment Guidelines
Pn No.
10
Position Loop Gain
11
Speed Loop Gain
12
Speed Loop Integration Time Constant
13
Speed Feedback Filter Time Constant
14
Torque Command Filter Time Constant
15
Feed-forward Amount
16
Feed-forward Command Filter
18
Position Loop Gain 2
19
Speed Loop Gain 2
1A
Speed Loop Integration Time Constant 2
1B
Speed Feedback Filter Time Constant 2
1C
Torque Command Filter Time Constant 2
1D
Notch Filter 1 Frequency
1E
Notch Filter 1 Width
20
Inertia Ratio
*1. Input the Inertia Ratio (Pn20). The inertia ratio can be measured with autotuning or set to a
calculated value. When the inertia ratio is unknown, set 300 in Pn20.
Parameter name
7-5 Manual Tuning
Guideline
27
15
37
0
152
0
0
27
15
37
0
152
1500
2
*1
7
7-18