4-2 Wiring
Item
Power supply capacity
Main circuit power
supply input (L1,
L2)
External
Regeneration
Resistor
connection (+, −)
4
Servomotor
connection
terminal (U, V,
*2
W,
)
Frame ground
No-fuse breaker or fuse
*3
capacity
*1. Values in parentheses ( ) are for using single-phase 200 V.
*2. Connect an OMRON Servomotor Power Cable to the Servomotor connection terminals.
*3. Use a no fuse breaker or a surge withstand fuse. The maximum inrush current is 20 A.
 Wire Size and Allowable Current (Reference)
The following table shows the allowable current when there are three power supply wires.
Use a current below these specified values.
600-V Heat-resistant Vinyl Wire (HIV)
AWG size
4-19
Unit
kVA
Rated
A(rms)
current
Wire size
Wire size
Rated
A(rms)
current
Maximum
momen-
A(rms)
tary
current
Wire size
Wire size
Screw size
---
Torque
N·m
A(rms)
Nominal
Configura-
cross-
sectional
(wires/mm
2
area (mm
)
20
0.5
19/0.18
---
0.75
30/0.18
18
0.9
37/0.18
16
1.25
50/0.18
14
2.0
R7D-BP01H
R7D-BP02HH
0.27
0.35
*1
(0.3)
0.7
1.6
*1
(1.5)
1.0
1.6
3.3
4.9
AWG14 min.
3
Allowable current (A) for ambient
Conductive
tion
resistance
2
)
(Ω/km)
30°C
39.5
26.0
24.4
15.6
7/0.6
9.53
R7D-BP02H
R7D-BP04H
0.42
(0.77)
1.1
(3.5)
AWG18
AWG18
1.6
4.9
AWG18
M4
1.2 to 1.4
2
temperature
40°C
50°C
6.6
5.6
4.5
8.8
7.0
5.5
9.0
7.7
6.0
12.0
11.0
8.5
23