Connection Example 2: Connecting to SYSMAC CJ1W-NC113/213/413 Position
Control Units
3-phase 200/240 VAC 50/60 Hz
CJ1W-NC113/213/413
Contents
No.
A1
24-V power supply for outputs
A2
0-V input (for output)
A6
CW (with a resistor)
A5
CW (without a resistor)
A8
CCW (with a resistor)
A7
CCW (without a resistor)
A9
X-axis dev. cntr. reset output
A13
X-axis origin input (24 V)
A12
X-axis origin common
A11
X-axis positioning complete input
A20
X-axis input common
A15
X-axis external interrupt input
A17
X-axis origin proximity input
A19
X-axis CCW limit input
X-axis CW limit input
A18
X-axis emerg. stop input
A16
Precautions
for Correct Use
NFB
R
S
T
R7A-CPB@S
24 VDC
24 VDC
X1
X1
24 VDC
XB
Incorrect signal wiring can cause damage to Units and the Servo Drive.
Leave unused signal lines open and do not wire them.
Use mode 2 for origin search.
Use the 24-VDC power supply for the command pulse inputs as a
dedicated power supply.
Do not share the power supply for brakes (24 VDC) with the 24-VDC power
supply for controls.
Recommended surge absorption diode: RU2 (Sanken Electric) or the
equivalent
Main circuit
power supply
Main circuit contactor
OFF
ON
X1
MC1
X1
R7D-BP@
Reactor
CN1
CNA
L1
L2
L3
22
+CW
−CW
23
P
24
B1
+CCW
−CCW
25
4
ECRST
CNB
14
GND
Red
21
Z
U
White
10
INP
V
Blue
W
Green/
Yellow
1
+24VIN
Encoder Cable
2
RUN
CN2
R88A-CRGB@C
13
0GND
9
/ALM
11
BKIR
26
FG
24 VDC
MC1
SUP
Surge suppressor
Servo error display
PL
MC1
Connect External Regeneration
Resistor when required.
@
R88M-G
Servomotor Power
Cable
@
R7A-CAB
S
M
E
Brake Cable
R88A-CAGA@B
XB
B
Appendix-2
App