Rotation Speed for Servomotor Rotation Detection
Pn62
Setting range
0 to 20000
 Set the number of rotations for the Servomotor Rotation Speed Detection Output (TGON) during
Internally Set Speed Control.
 The Servomotor Rotation Speed Detection Output (TGON) will turn ON if the Servomotor speed
exceeds the set speed regardless of the direction of rotation.
 There is a hysteresis of 10 r/min, so set a value higher than 10.
Deviation Counter Overflow Level
Pn63
Setting range
0 to 32767
 Set the detection level for the deviation counter overflow alarm.
 The alarm level is the setting value multiplied by 256 pulses.
Deviation Counter Overflow Alarm Disabled
Pn64
Setting range
0 or 1
 The deviation counter overflow alarm can be disabled so that it does not occur.