Rotation Speed for Servomotor Rotation Detection
Pn62
Setting range
0 to 20000
Set the number of rotations for the Servomotor Rotation Speed Detection Output (TGON) during
Internally Set Speed Control.
The Servomotor Rotation Speed Detection Output (TGON) will turn ON if the Servomotor speed
exceeds the set speed regardless of the direction of rotation.
There is a hysteresis of 10 r/min, so set a value higher than 10.
Deviation Counter Overflow Level
Pn63
Setting range
0 to 32767
Set the detection level for the deviation counter overflow alarm.
The alarm level is the setting value multiplied by 256 pulses.
Deviation Counter Overflow Alarm Disabled
Pn64
Setting range
0 or 1
The deviation counter overflow alarm can be disabled so that it does not occur.
Explanation of Settings
Setting
0
1
Pn65
Not used. (Do not change setting.)
Unit
r/min
Speed
Pn62
Reverse
TGON
Unit
× 256 pulses
Unit
---
Explanation
Enabled
Disabled
5-10 User Parameters
Default setting
50
Power OFF → ON
Forward
Pn62
Default setting
100
Power OFF → ON
Default setting
0
Power OFF → ON
Internally set speed
---
Position
---
Position
---
5-56
5