4-3 Wiring Conforming to EMC Directives
Noise Filters for the Power Supply Input
 Use a noise filter to attenuate external noise and reduce noise emitted from the Servo Drive.
 Select a noise filter with a rated current that is at least two times greater than the effective load
current (the rated current of the main circuit power supply input given in Main Circuit Wiring on
page 4-18).
NEC TOKIN
4
Okaya Electric
Industries Co.,
ltd.
TDK
Note 1. To attenuate noise at low frequencies below 200 kHz, use an isolation transformer and a
Note 2. To attenuate noise at high frequencies over 30 MHz, use a ferrite core and a high-frequency
Note 3. If multiple Servo Drives are connected to a single noise filter, select a noise filter with a rated
Noise Filters for Servomotor Output
 Use noise filters without built-in capacitors on the Servomotor output lines.
 Select a noise filter with a rated current at least two times the Servo Drive's continuous output
current.
 The following table shows the recommended noise filters for Servomotor output.
OMRON
Note 1. Servomotor output lines cannot use the same noise filters for power supplies.
Note 2. Typical noise filters are made for power supply frequencies of 50/60 Hz. If these noise filters
4-33
Maker
Model
GT-2050
GT-2100
GT-2150
GT-2200
HFP-2153
HFP-2303
SUP-EW5-ER-6
SUP-EW10-ER-6
SUP-EW15-ER-6
SUP-EW20-ER-6
SUP-EW30-ER-6
3SUP-HU10-ER-6
3SUP-HU20-ER-6
ZRCS2006-00S
ZRCS2010-00S
ZRCS2020-00S
ZRCS2030-00S
noise filter.
noise filter with a feed through capacitor.
current at least two times the total rated current of all the Servo Drives.
Maker
Model
3G3AX-NF001
3G3AX-NF002
are connected to the PWM output of the Servo Drive, an extremely large (about 100 times
larger) leakage current will flow through the noise filter's condenser and the Servo Drive
could be damaged.
Rated current
Applicable standards
5 A
10 A
UL, CSA, VDE, TUV
15 A
20 A
15 A
UL, CSA, TUV
30 A
5 A
10 A
15 A
20 A
UL, CSA, SEMKO
30 A
10 A
20 A
6 A
10 A
UL, CSA, NEMKO
20 A
30 A
Rated current
6 A
For inverter output
12 A
Remarks
Single-phase
Three-phase
Single-phase
Three-phase
Single-phase
Remarks

Advertisement