Alarm Type:
Rising Event:
Rising Threshold:
Falling Event:
Falling Threshold:
Interval:
Owner:
Operation:
Note:
When alarm variables exceed the Threshold on the same direction continuously for several
times, an alarm event will only be generated on the first time, that is, the Rising Alarm and
Falling Alarm are triggered alternately for that the alarm following to Rising Alarm is certainly a
Falling Alarm and vice versa.
Specify the type of the alarm.
Rising: When the sampled value exceeds the Rising
•
Threshold, an alarm event is triggered.
Falling: When the sampled value is under the Falling
•
Threshold, an alarm event is triggered.
All: The alarm event will be triggered either the sampled
•
value exceeds the Rising Threshold or is under the Falling
Threshold.
Select the index of the corresponding event which will be
triggered if the sampled value is larger than the rising
Threshold.
Enter the rising counter value that triggers the rising threshold
alarm, ranging from 1 to 2147483647.
Select the index of the corresponding event which will be
triggered if the sampled value is lower than the Falling
Threshold.
Enter the falling counter value that triggers the falling
threshold alarm, ranging from 1 to 2147483647.
Enter the alarm interval time in seconds, ranging from 10 to
3600.
Enter the name of the device or user that defines the entry.
Click "Edit" to edit the alarm group entry.
385
Return to CONTENTS