  • Page 1 Инструкция для TP-Link TL-SG2424 (Установка) Перейти в карточку товара 8 800 775 98 98...
  • Page 2 Enterprise Networking Solution Installation Guide Gigabit Smart Switch...
  • Page 3 Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD.
  • Page 4: Chapter 1 Introduction

    Network Administrator Due to the similarity in structure of the Gigabit Smart Switch series, in this Installation Guide we take TL-SG2216 as an example to illustrate Chapter 2 Installation, Chapter 3 Lightning Protection and Chapter 4 Connection and Chapter 5 Configuration.
  • Page 5: Table Of Contents

    Chapter 1 Introduction ——————————— 01 Product Overview ..............01 Appearance ................01 Chapter 2 Installation ———————————— 04 Package Contents ..............04 Safety Precautions ..............04 Installation Tools..............06 Product Installation ..............07 Chapter 3 Lightning Protection ———————— 09 Cabling Reasonably..............09 Connect to Ground..............11 Equipotential Bonding ............12 Use Lightning Arrester ............13 Chapter 4 Connection ———————————...
  • Page 6: Front Panel

    Front Panel The front panel of TL-SG2216 is shown as the following figure. Reset LEDs 10/100/1000Mbps RJ45 Port...
  • Page 7: Rear Panel

    1000Mbps. Each has a corresponding Link/Act LED and a 1000Mbps LED. SFP Port Designed to install the SFP module. TL-SG2216/TL-SG2424 Switch features 2/4 SFP transceiver slots that are shared with the associated RJ45 ports. The associated two ports are referred as a “Combo” ports, which means they cannot be used simultaneously, otherwise only SFP port works.
  • Page 8 The rear panel of TL-SG2424 is shown as the following figure. Grounding Terminal Power Socket Figure 1-4 Rear Panel TL-SG2424 Grounding Terminal The Switch already comes with lightning protection mechanism. You can also ground the Switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed information, please refer to Chapter 3 Lightning Protection.
  • Page 9: Chapter 2 Installation

    Gigabit Smart Switch Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. One Switch One Power Cord This Installation Guide One Resource CD Two mounting brackets and the To avoid any device damage and bodily injury caused by improper use, please observe the following rules.
  • Page 10 Site Requirements Temperature/Humidity Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device. For normal temperature and humidity of the device, please check the following table.
  • Page 11: Chapter 3 Lightning Protection

    Gigabit Smart Switch Lightning Protection Extremely high voltage currents can be produced instantly when lightning occurs and the air in the electric discharge path can be instantly heated up to 20,000 . As this instant current is strong enough to damage electronic devices, more effective lightning protection measures should be taken.
  • Page 12: Desktop Installation

    Desktop Installation To install the device on the desktop, please follow the steps: Set the device on a flat surface strong enough to support the entire weight of the device with all fittings. Remove the adhesive backing papers from the rubber feet. Turnover the device and attach the supplied rubber feet to the recessed areas on the bottom at each corner of the device.
  • Page 13 Gigabit Smart Switch Rack Figure 2-3 Rack Installation Caution: Please set 5~10cm gaps around the device for air circulation. Please avoid any heavy thing placed on the device. Please mount devices in sequence from the bottom to top of the rack and ensure a certain clearance between devices for the purpose of heat dissipation.
  • Page 14 In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devices. Note: It's not recommended using Ethernet cables outdoors. When cabling outdoors, please use a signal lightning arrester.
  • Page 15: Requirements For Cabling Indoors

    Gigabit Smart Switch Requirements for Cabling Indoors When cabling indoors, keep a certain distance away from the devices that may cause high-frequency interferences, such as down-conductor cable, powerline, power transformer and electromotor. The main cable should be paved in the metal raceway of the access shaft. When cabling, keep the loop area formed by the cable itself as small as possible.
  • Page 16: Connect To Ground

    Min Parallel Cable Pave Way Length (mm) Parallel cabling 2~5kVA One is in the grounded metal raceway or metal pipe powerline The both are in the grounded metal raceway or metal pipe Parallel cabling >5kVA One is in the grounded metal raceway or metal pipe powerline The both are in the grounded metal raceway or metal pipe...
  • Page 17: Equipotential Bonding

    Gigabit Smart Switch Note: The grounding bar and the ground cable are not provided with our product. If needed, please self purchase them. Connecting to the Ground via the Power Supply If the device is installed in the normal environment, the device can be grounded via the PE (Protecting Earth) cable of the AC power supply as shown in the following figure.
  • Page 18 Grounding Terminal Equipotential Bonding Cable Ground Cable Grounding Bar Figure 3-3 Equipotential Bonding When equipotential bonding, please note that the cable should be copper wrapped Kelly with its area being 6mm at least. The shorter cable the better, and use a grounding bar to establish an equipotential bonding point.
  • Page 19: Chapter 4 Connection

    Gigabit Smart Switch rules: The port rate of the signal lightning arrester should match the rate of the desired port on the device. If it is not matched, this signal lighting arrester will not work. Purchase a standard lightning arrester. Install signal lightning arrester near the protected device and connect it to the ground via a shorter ground cable.
  • Page 20: Ethernet Port

    Connect a Ethernet port of the Switch to the computer by RJ45 cable as the following figure shown. RJ45 Port RJ45 Cable Figure 4-1 Connecting the RJ45 Port Connect the SFP port to a SFP module. If an SFP transceiver (purchased separately) is installed in a slot and has a valid link on the port, the associated RJ45 port will be disabled and cannot be used.
  • Page 21: Initialization

    Gigabit Smart Switch After completing the installation, please verify the following items: There are 5~10cm of clearance around the sides of the device for ventilation and the air flow is adequate. The voltage of the power supply meets the requirement of the input voltage of the device. The power socket, device and rack are well grounded.
  • Page 22 To access the GUI of the Switch, open a web browser and type the default management address http://192.168.0.1 in the address field of the browser, then press the Enter key. Figure 5-1 Web Browser Note: To log on to the GUI of the Switch, the IP address of your PC should be set in the same subnet addresses of the Switch.
  • Page 23 Gigabit Smart Switch Figure 5-3 Main Page of the Switch You can log on to the Switch and access the CLI by Logging on to the Switch remotely by a Telnet connection through an Ethernet port. To log on to the switch by a Telnet connection, please take the following steps: Make sure the switch and the PC are in the same LAN.
  • Page 24 Type cmd in the prompt Run window as Figure 5-5 and click OK. Figure 5-5 Run Window Type telnet 192.168.0.1 in the command prompt shown as Figure 5-6, and press the Enter button. Figure 5-6 Connecting to the Switch...
  • Page 25 Gigabit Smart Switch Power off and restart the Switch. When you are prompted that “Press CTRL-B to enter the bootUtil” in the hyper terminal, please press CTRL-B Press the Reset buttom for at least 5 seconds to reset the system. The system will be reset to the factory default settings, and the default login user name and password are both admin.
  • Page 26 Item Content IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX/100Base-FX Standards IEEE 802.3ab 1000Base-T IEEE 802.3z 1000Base-X IEEE 802.3x Flow Control 10Base-T: UTP/STP of Cat. 3 or above (maximum 100m) 100Base-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100m) Transmission Medium 100Base-FX: MMF or SMF SFP Module (Optional) 1000Base-T: 4-pair UTP/STP of Cat.
  • Page 27 Gigabit Smart Switch For more help, please go to: www.tp-link.com/support/faq.asp To download the latest Firmware, Driver, Utility and User Guide, go to: www.tp-link.com/support/download.asp For all other technical support, please contact us by using the following details: Global Tel: +86 755 26504400 E-mail: support@tp-link.com...