54
Commissioning
Then the Save WAGO iParameter Set dialog opens. Enter a name for the
parameter file and select the folder where the file is to be saved. Then click
[Save] to save the file to the specified location.
To print the iParameter values and the information on the parameter file, click the
[Print] button in the WAGO Safety Editor toolbar.
7.3.2

OFFLINE Mode

OFFLINE mode is used to create or change iParameter settings of an F I/O
module in a parameter file.
7.3.2.1

Reading from a Parameter File

When WAGO Safety Editor is launched, specify whether you want to change a
parameter file that is already saved on the computer or to create a new
parameter file.
If you want to change a parameter file that saved on the computer, you are taken
to the storage location of the last saved parameter file.
If you want to create a new parameter file, you are taken to the storage location
of the default parameter files. Based on the names of these files, you can tell the
type of the supported F I/O module.
In the Open WAGO iParameter Set dialog, enter the name of the parameter file
to load. Then click the [Open] button to load the selected file.
Another iParameter Set Description dialog opens. In this dialog, check the
information concerning the project, changes made and persons responsible and
change the information if necessary. Click [OK] to confirm the information
entered.
7.3.2.2

Writing to a Parameter File

In the Input column of the iParameter set table of WAGO Safety Editor, you can
make the desired changes to the iParameter values.
After selecting an iParameter, you can select the parameter values from a
selection field or enter them directly.
If all settings are correct, save the iParameter set in a parameter file. Click the
[Save] button in the WAGO Safety Editor toolbar.
The iParameter Set Description dialog opens for a more detailed description of
the parameter file. In this dialog, enter information about the project, the changes
made and the persons responsible. Click the [OK] button to confirm the
information you entered.
Then the Save WAGO iParameter Set dialog opens. Enter a name for the
parameter file and select the folder where the file is to be saved. Then click
[Save] to save the file to the specified location.