Daikin VRV III Manual page 55

Hide thumbs Also See for VRV III:
Table of Contents

Advertisement

Specifications
Ceiling Mounted Cassette (Round Flow) Type
Model
1 Cooling Capacity (19.5°CWB)
2 Cooling Capacity (19.0°CWB)
Casing
Dimensions: (H×W×D)
Rows×Stages×Fin Pitch
Coil (Cross
Fin Coil)
Face Area
Model
Type
Motor Output × Number
of Units
Fan
Air Flow Rate (HH/H/L)
Drive
Temperature Control
Sound Absorbing Thermal Insulation Material
Liquid Pipes
Gas Pipes
Piping
Connections
Drain Pipe
Mass (Weight)
4 Sound Level (HH/H/L) (220-240V)
Safety Devices
Refrigerant Control
Connectable Outdoor Unit
Model
Panel Color
Decoration
Dimensions: (H×W×D)
Panels
(Option)
Air Filter
Weight
Standard Accessories
Drawing No.
Note:
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5 m, level difference : 0 m.
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5 m, level difference : 0 m.
3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
4 Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are
normally somewhat higher as a result of ambient conditions.
5 Refer to page 56 for Fan Motor Input.
50
FXFQ63PVE
kcal/h
6,300
Btu/h
24,900
kW
7.3
kW
7.1
Galvanized Steel Plate
mm
246×840×840
mm
2×10×1.2
0.446
QTS48C15M
Turbo Fan
W
56×1
m³/min
19/16.5/13.5
cfm
671/583/477
Direct Drive
Microprocessor Thermostat
for Cooling and Heating
Polyurethane Form
φ
mm
9.5 (Flare Connection)
φ
mm
15.9 (Flare Connection)
VP25
mm
External Dia. 32
(
)
Internal Dia. 25
kg
22
dBA
34/31/28
Fuse
Electronic Expansion Valve
R-410A VRV PA Series
BYCP125K-W1
Fresh White
mm
50×950×950
Resin Net
(with Mold Resistant)
kg
5.5
Operation Manual.
Installation Manual.
Paper Pattern for
Installation.
Drain Hose. Clamp Metal.
Washer Fixing Plate.
Sealing Pads. Clamps.
Screws. Washer for
Hanging Bracket. Insulation
for Fitting.
Installation Guide.
FXFQ80PVE
FXFQ100PVE
8,000
31,700
9.3
9.0
Galvanized Steel Plate
Galvanized Steel Plate
246×840×840
288×840×840
2×10×1.2
0.446
QTS48C15M
QTS48C15M
Turbo Fan
56×1
21/18/15
742/636/530
1,130/918/706
Direct Drive
Direct Drive
Microprocessor Thermostat
Microprocessor Thermostat
for Cooling and Heating
for Cooling and Heating
Polyurethane Form
Polyurethane Form
φ
φ
9.5 (Flare Connection)
9.5 (Flare Connection)
φ
φ
15.9 (Flare Connection)
15.9 (Flare Connection)
VP25
External Dia. 32
External Dia. 32
(
)
(
Internal Dia. 25
Internal Dia. 25
22
36/33.5/31
Fuse
Electronic Expansion Valve
Electronic Expansion Valve
R-410A VRV PA Series
R-410A VRV PA Series
BYCP125K-W1
BYCP125K-W1
Fresh White
Fresh White
50×950×950
50×950×950
Resin Net
(with Mold Resistant)
(with Mold Resistant)
5.5
Operation Manual.
Operation Manual.
Installation Manual.
Installation Manual.
Paper Pattern for
Paper Pattern for
Installation.
Installation.
Drain Hose. Clamp Metal.
Drain Hose. Clamp Metal.
Washer Fixing Plate.
Washer Fixing Plate.
Sealing Pads. Clamps.
Sealing Pads. Clamps.
Screws. Washer for
Screws. Washer for
Hanging Bracket. Insulation
Hanging Bracket. Insulation
for Fitting.
for Fitting.
Installation Guide.
Installation Guide.
C : 3D060255
: http://splitoff.ru/tehn-doc.html
ED34-862
FXFQ125PVE
10,000
12,500
39,600
49,500
11.6
14.5
11.2
14.0
Galvanized Steel Plate
288×840×840
2×12×1.2
2×12×1.2
0.535
0.535
QTS48C15M
Turbo Fan
Turbo Fan
120×1
120×1
32/26/20
33/28/22.5
1,165/989/794
Direct Drive
Microprocessor Thermostat
for Cooling and Heating
Polyurethane Form
φ
9.5 (Flare Connection)
φ
15.9 (Flare Connection)
VP25
VP25
External Dia. 32
)
(
Internal Dia. 25
25
25
43/37.5/32
44/39/34
Fuse
Fuse
Electronic Expansion Valve
R-410A VRV PA Series
BYCP125K-W1
Fresh White
50×950×950
Resin Net
Resin Net
(with Mold Resistant)
5.5
5.5
Operation Manual.
Installation Manual.
Paper Pattern for
Installation.
Drain Hose. Clamp Metal.
Washer Fixing Plate.
Sealing Pads. Clamps.
Screws. Washer for
Hanging Bracket. Insulation
for Fitting.
Installation Guide.
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3
)