Specifications
BEV Units
Model
Power Supply
Casing
Dimensions: (H×W×D)
mm
Sound Absorbing Thermal Insulation
Material
Liquid Pipes
Indoor
Unit
Gas Pipes
Piping
Connection
Liquid Pipes
Outdoor
Unit
Suction Gas Pipes
Machine Weight (Mass)
kg
Standard Accessories
Drawing No.
Connection Example
Power
Power
supply
supply
Control
Control
Wiring
Wiring
BRC1C62
Consideration matter
- When connecting centralized-control device, it is necessary to install an interface
adaptor for SkyAir series in an indoor unit.
- Distance between indoor unit and –BEV unit must be within 5m.
Outline figure
Installation pattern / maintenance
1. Level installation (It hangs by two hangers)
*1; Service space for switch box.
(Service access panel is required for the bottom side. When there is nothing, 350 or more spaces are required. )
*2; For electric valve drive part's maintenance. (a control box is removed)
384
BEVQ71MAVE
1 Phase 50Hz 220~240V
Galvanized Steel Plate
100×350×225
Flame and Heat Resistant Foamed
Polyethylene
9.5mm (Flare Connection)
15.9mm (Flare Connection)
9.5mm (Flare Connection)
15.9mm (Flare Connection)
3.0
Installation manual, Gas piping
connections, Insulation for fitting,
Sealing material, Clamps
4D045387A
Transmission
Transmission
line
line
line
line
Terminal block
Piping part cover
Electric valve drive part
Hanger bolt
Liquid pipe
Service
space*2
100 or more
Installation
space
150 or more
Service access panel (450 x 450 )
BEVQ100MAVE
1 Phase 50Hz 220~240V
Galvanized Steel Plate
100×350×225
Flame and Heat Resistant Foamed
Polyethylene
9.5mm (Flare Connection)
15.9mm (Flare Connection)
9.5mm (Flare Connection)
15.9mm (Flare Connection)
3.0
Installation manual, Gas piping
connections, Insulation for fitting,
Sealing material, Clamps
4D045387A
1. Wiring Work
•The connecting line between SkyAir Indoor Unit
– BEV Unit : 3 cores...like a Transmission Line
•BEV Unit's power supply line;
Single phase 2 line...like a VRV Indoor unit
•BEV Unit – other VRV indoor unit or outdoor unit –
: 2 cores...DIII network wiring (super wiring)
2. Piping work
SkyAir side,Outdoor Unit Side,They are both flare
connection.
Gas pipe (With Thermistor,
Insulation pipe cover)
PC board
SW.BOX cover
Hanger
(Wall surface attachment is also possible)
Liquid pipe
2. Vertical Installation
(Wall Surface Mounted)
Gas pipe
Service space*1
Screw fixed
(x2 Screws x2 place)
: http://splitoff.ru/tehn-doc.html
ED34-862
BEVQ125MAVE
1 Phase 50Hz 220~240V
Galvanized Steel Plate
100×350×225
Flame and Heat Resistant Foamed
Polyethylene
9.5mm (Flare Connection)
15.9mm (Flare Connection)
9.5mm (Flare Connection)
15.9mm (Flare Connection)
3.5
Installation manual, Gas piping
connections, Insulation for fitting,
Sealing material, Clamps
4D045388A