Daikin VRV III Manual page 125

Hide thumbs Also See for VRV III:
Table of Contents

Advertisement

Accessories
Precautions
This kit can be mounted to an ceiling mounted cassette-type air conditioner <round flow>.
According to the chart below, check the model name of indoor unit, then mount the kit.
This kit cannot be used for the mounting of humidifier and branch duct.
Combination table
Model name
SkyAir
KDTP55K80
VRV
SkyAir
KDTP55K160
VRV
Parts content
Name
1
Side insulator plate (1)
778mm
80
A=245mm
160
A=287mm
Shape
Slit
Number of pieces
1
Name
6
Top insulator plate (2)
Shape
Number of pieces
1
Sticking Procedure
Perform the work on soft cloth to prevent damage to the indoor unit and panel.
<Procedure>
(1) According to the sticking procedure for the side insulator plate, stick the side insulator plates (1 to 4) in sequential
order without leaving any gap in between. (Figure 1)
(When mounting the fresh air intake kit (KDDP55X160), cut off the side insulator plate (2) with a cutter knife along the
perforation. The cut-off insulator is no longer needed.)
(2) Stick the top insulator plates (1 to 3) without leaving any gap in between. Also, stick the top insulator plates without
leaving any gap against the side insulator plates all the way around. (Figure 2)
(3) Hang the product.
(4) Stick the suspension bracket insulator to the suspension bracket together with the washer and bolt. (Figure 3)
(5) Lastly, stick the panel insulator to the backside of the panel. (Figure 4)
3
Side insulator plate (3)
Slit
Slit
4
Side insulator plate (4)
Sticking reference for
2
side insulator plate (2)
Sticking reference for
side insulator plate (3)
At the suspension bracket section,
the slit must be passed through.
3
Sticking reference for
side insulator plate (4)
Sticking procedure for side insulator plate
120
Installable indoor unit model name
FCQ(N)71KVEA
FXFQ25~80PVE
FCQ(N)100·125·140KVEA
FXFQ100·125PVE
2
Side insulator plate (2)
3
765mm
80
A=245mm
160
A=287mm
1
7
Top insulator plate (3)
8
suspension bracket insulator
1
4
2
Side insulator plate (2)
* Fresh air intake kit
When mounting (KDDP55X160), cut off
the insulator along the perforation.
Perforation
Suspension bracket
(4 points)
Slit
1
Side insulator plate (1)
Suspension bracket
(4 points)
At the suspension bracket section,
the slit must be passed through.
1
Sticking reference for
side insulator plate (1)
4
(Figure 1)
Side insulator plate (3)
4
Side insulator plate (4)
769mm
772mm
80
A=245mm
160
A=287mm
Slit
1
1
9
Panel insulator
· This manual
4
7
Top insulator plate (3)
8
Suspension bracket insulator
* After hanging the product, stick the
suspension bracket insulator.
Match these corners
before sticking.
Panel insulator
: http://splitoff.ru/tehn-doc.html
5
Top insulator plate (1)
80 A=245mm
160
A=287mm
1
Others
6
Top insulator plate (2)
5
Top insulator plate (1)
(Figure 2)
(Figure 3)
9
Panel insulator
(Figure 4)
JC : 3P179341C
ED34-862