® • Outdoor Unit • VRV III heat recovery, with connection to heating only hydrobox • REYAQ-P TABLE OF CONTENTS REYAQ-P Specifications ............2 Technical Specifications .
3.51 3.19 4.27 4.24 4.09 3.91 Maximum number of connectable indoor units Indoor index Min. connection Nom. Max. Casing Colour Daikin White Material Painted galvanized steel plate Dimensions Unit Height 1,680 Width 1,300 Depth Packed unit Height 1,885 Width 1,425...
Page 5
® • Outdoor Unit • VRV III heat recovery, with connection to heating only hydrobox • REYAQ-P Specifications 1-1 Technical Specifications REYAQ10P REYAQ12P REYAQ14P REYAQ16P Piping Liquid Type Braze connection connections 9.52 12.7 Type Braze connection 22.2 28.6 Discharge Type Braze connection 19.1 22.2...
® • Outdoor Unit • VRV III heat recovery, with connection to heating only hydrobox • REYAQ-P Specifications 1-2 Electrical Specifications REYAQ10P REYAQ12P REYAQ14P REYAQ16P Power supply Phase Frequency Voltage 380-415 Voltage range Min. Max. Current Zmax Text 0.27 Current - 50Hz Maximum running current 22.1 22.3 32.8...
® • Outdoor Unit • VRV III heat recovery, with connection to heating only hydrobox • REYAQ-P Centre of gravity 6 - 1 Centre of Gravity ® • VRV Systems • Outdoor Unit...
® • Outdoor Unit • VRV III heat recovery, with connection to heating only hydrobox • REYAQ-P Wiring diagrams 8 - 1 Wiring Diagrams - Three Phase ® • VRV Systems • Outdoor Unit...
Page 33
® • Outdoor Unit • VRV III heat recovery, with connection to heating only hydrobox • REYAQ-P Wiring diagrams 8 - 1 Wiring Diagrams - Three Phase ® • VRV Systems • Outdoor Unit...
® • Outdoor Unit • VRV III heat recovery, with connection to heating only hydrobox • REYAQ-P Sound data 10 - 1 Sound Power Spectrum REYAQ10P REYAQ12P Octave band center frequency (Hz) Octave band center frequency (Hz) 3TW59927-2A 3TW59927-2A REYAQ14P REYAQ16P Octave band center frequency (Hz) Octave band center frequency (Hz)
® • Outdoor Unit • VRV III heat recovery, with connection to heating only hydrobox • REYAQ-P Sound data 10 - 2 Sound Pressure Spectrum REYAQ10P REYAQ12P Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency (Hz) Octave band center frequency (Hz) 3TW59927-1A 3TW59927-1A...
® • Outdoor Unit • VRV III heat recovery, with connection to heating only hydrobox • REYAQ-P Installation 11 - 1 Refrigerant Pipe Selection Selection of piping size C. Piping between refrigerant branch kit or branch selector box and indoor unit Pipe size for direct connection to indoor unit must be the same NOTICE as the connection size of the indoor unit.
Page 38
® • Outdoor Unit • VRV III heat recovery, with connection to heating only hydrobox • REYAQ-P Installation 11 - 1 Refrigerant Pipe Selection For refnets joints other than the first branch (example refnet joint b and c), select the proper branch kit model based on the Maximum allowable lengths total capacity index of all indoor units connected after the refrigerant branch.
® • Outdoor Unit • VRV III heat recovery, with connection to heating only hydrobox • REYAQ-P Operation range 12 - 1 Operation Range REYAQ-P Heating mode Cooling mode Indoor temperature (°CDB) Indoor temperature (°CDB) Remark Operation range is valid for combination of REYAQ-P and direct expansion indoor units. 3TW60653-1A(2) ®...