ED34-862
Ceiling Mounted Duct Type
Model
1 Cooling Capacity (19.5°CWB)
2 Cooling Capacity (19.0°CWB)
Casing
Dimensions: (H×W×D)
Rows×Stages×Fin Pitch
Coil (Cross
Fin Coil)
Face Area
Model
Type
Motor Output × Number
of Units
Fan
Air Flow Rate (HH/H/L)
External Static
Pressure
Drive
Temperature Control
Air Filter
Liquid Pipes
Gas Pipes
Piping
Connections
Drain Pipe
Mass (Weight)
6 Sound Level (HH/H/L) dBA
Safety Devices
Refrigerant Control
Connectable Outdoor Unit
Standard Accessories
Drawing No.
Note:
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5 m, level difference : 0 m.
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5 m, level difference : 0 m.
3 External static pressure is changeable in 13 or 14 stages within the ( ) range by remote controller.
4 Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its colorimetric method (gravity method)
50% or more.
5 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
6 Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are
normally somewhat higher as a result of ambient conditions.
7 Refer to page 255 for Fan Motor Input.
FXMQ-P
FXMQ100PVE
kcal/h
10,000
Btu/h
39,600
kW
11.6
kW
11.2
Galvanized Steel Plate
mm
300×1,400×700
mm
3×16×1.75
0.383
Sirocco Fan
W
350×1
m³/min
32/27/23
cfm
1,130/953/812
Pa
Standard 100 (200-50
Direct Drive
Microprocessor Thermostat for Cooling and Heating
4
φ
mm
9.5 (Flare Connection)
φ
mm
15.9 (Flare Connection)
VP25
mm
External Dia. 32
(
Internal Dia. 25
kg
46
220V
43/41/39
240V
43/41/39
Fuse.
Fan Driver Overload Protector.
Electronic Expansion Valve
R-410A PA Series
Operation Manual. Installation Manual. Drain Hose. Clamp
Metal. Insulation for Fitting. Sealing Pads. Clamps.
Washers. Screws. Air Discharge Flange. Air Suction
Flange.
3)
Microprocessor Thermostat for Cooling and Heating
)
Fan Driver Overload Protector.
Operation Manual. Installation Manual. Drain Hose. Clamp
Metal. Insulation for Fitting. Sealing Pads. Clamps.
Washers. Screws. Air Discharge Flange. Air Suction
Flange.
C : 3D060388A
: http://splitoff.ru/tehn-doc.html
Specifications
FXMQ125PVE
12,500
49,500
14.5
14.0
Galvanized Steel Plate
300×1,400×700
3×16×1.75
0.383
Sirocco Fan
350×1
39/33/28
1,377/1,165/988
Standard 100 (200-50
3)
Direct Drive
4
φ
9.5 (Flare Connection)
φ
15.9 (Flare Connection)
VP25
External Dia. 32
(
)
Internal Dia. 25
46
44/42/40
44/42/40
Fuse.
Electronic Expansion Valve
R-410A PA Series
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3
247
7