fire or other damage to the equipment. Be sure to use only accessories made by Daikin which are specifically designed for use with the equipment and have them installed by a professional. Ask your dealer to move and reinstall the air conditioner.
Do not operate the air conditioner when using a room fumigation Cautions - type insecticide. Failure to observe could cause the chemicals to become Do not use the air conditioner for other purposes. deposited in the unit, which could endanger the health of those In order to avoid any quality deterioration, do not use the unit for who are hypersensitive to chemicals.
EMOTE CONTROLLER PERATION PROCEDURE Refer to the operation manual of the remote controller. Operation procedure varies according to the combination of outdoor unit and remote controller. Read "3. What to do before operation" on page HANGEOVER SWITCH AME AND To protect the unit, turn on the main power switch 6 hours before FUNCTION OF EACH SWITCH (See figure 2) operation.
Explanation of heating operation For systems with cool/heat changeover remote control switch (See figure 5) It may take longer to reach the set temperature for general heating operation than for cooling operation. Select cooling operation mode with the cool/heat changeover remote control switch.
7.4. Setting the master remote controller NERGY SAVING AND OPTIMUM OPERATION When the system is installed as shown in figure 8 (RXYQ + RXYSQ – the outdoor unit is connected to several indoor units) and figure 9 Observe the following precautions to ensure the system operates (REMQ –...
Symptom 3: Fan operation is possible, but cooling and heating do not AINTENANCE work. Immediately after the power is turned on. The micro computer is getting ready to operate. Wait 10 Pay attention to the fan. minutes. It is dangerous to inspect the unit while the fan is running. Be sure to turn off the main switch and to remove the fuses Symptom 4: The fan strength does not correspond to the setting.
Symptom 8.2: Indoor unit, outdoor unit The operation switch does not work well. A continuous low hissing sound is heard when the system is in Measure: Turn off the power. cooling or defrost operation. If the display , the unit number and the operation lamp TEST This is the sound of refrigerant gas flowing through both indoor flash and the malfunction code appears.
12. A FTER SALES SERVICE AND WARRANTY Table 1 indicates main components. NOTE Refer to your maintenance and inspection contract Warranty period for more details. This product includes a warranty card that was filled out by the Table 1 indicates recommended intervals of dealer at the time of installation.