B.3 Input Signal Selections
User
Digit
Constant
Place
Pn50A
0
1
1
Pn50A
2
3
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
The following list shows input signal selections and their factory settings.
Name
Setting
Input Signal Al-
0
location Mode
location Mode
1
/S-ON Signal
/S-ON Signal
0
Mapping (Servo
Mapping (Servo
1
ON when low.)
ON when low.)
2
3
4
5
6
7
8
9
A
B
C
D
E
F
/P-CON Signal
0 to F
Mapping (P con-
trol when low.)
P-OT Signal
0 to F
Mapping (Over-
travel when
high.)
Contents
Sets the input signal allocation for the sequence to the same
one as for the SGDB Servopack. *
Possible to freely allocate the input signals.
Inputs from the SI0 (CN1-40) input terminal.
Inputs from the SI1 (CN1-41) input terminal.
Inputs from the SI2 (CN1-42) input terminal.
Inputs from the SI3 (CN1-43) input terminal.
Inputs from the SI4 (CN1-44) input terminal.
Inputs from the SI5 (CN1-45) input terminal.
Inputs from the SI6 (CN1-46) input terminal.
Sets signal ON.
Sets signal OFF.
Inputs the reverse signal from the SI0 (CN1-40) input termi-
nal.
Inputs the reverse signal from the SI1 (CN1-41) input termi-
nal.
Inputs the reverse signal from the SI2 (CN1-42) input termi-
nal.
Inputs the reverse signal from the SI3 (CN1-43) input termi-
nal.
Inputs the reverse signal from the SI4 (CN1-44) input termi-
nal.
Inputs the reverse signal from the SI5 (CN1-45) input termi-
nal.
Inputs the reverse signal from the SI6 (CN1-46) input termi-
nal.
Same as above.
Same as above.
B -11
B.3 Input Signal Selections
Factory
Setting
0
1
0: SI0
0: SI0
1: SI1
2: SI2
B