Inspection, Maintenance, and Troubleshooting
9.2.1 Troubleshooting Problems with Alarm Displays
9
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
J J A.03
A.03: Main Circuit Detector Error
Display and Outputs
Alarm Outputs
Alarm Code Outputs
ALO1
ALO2
OFF
OFF
Note OFF: Output transistor is OFF (alarm state).
Status and Remedy for Alarm
At power ON
Cause
A
Circuit board (1PWB or 2PWB) defective.
J J A.04
A.04: User Constant Setting Error
Display and Outputs
Alarm Outputs
Alarm Code Outputs
ALO1
ALO2
OFF
OFF
Note OFF: Output transistor is OFF (alarm state)
Status and Remedy for Alarm
At power ON
Cause
A
An out-of-range user constant was previously
set or loaded.
B
Circuit board (1PWB) defective.
ALM
Output
Output
ALO3
OFF
OFF
A
Replace Servopack.
ALM
Output
Output
ALO3
OFF
OFF
A, B
S Reset all user constants in range.
S Otherwise, re-load correct user constant.
Replace Servopack.