The multiturn limit setting in the Encoder can be changed only when the Multiturn Limit Disagreement alarm
has occurred. After changing the setting, turn the power supply OFF and then back ON.
J J Changing the Setting with the Hand-held Digital Operator
1. Press the DSPL/SET Key to select the auxiliary function mode.
2. Select the user function Fn013. Press the Left or Right Cursor Key to select the digit to set,
and then press the Up or Down Cursor Key to change the number.
3. Press the DATA/ENTER Key. The following display will appear.
4. Press the DSPL/SET Key. The following display will appear and the multiturn limit setting
in the absolute encoder will be changed.
5. Press the DATA/ENTER Key to return to the auxiliary function mode.
This completes the procedure to change the multiturn limit setting in the absolute encoder. Turn
the power supply OFF and then back ON.
J J Changing the Setting with the Built-in Panel Operator
1. Press the DSPL/SET Key to select the auxiliary function mode.
2. Press the Up or Down Cursor Key to select the user constant Fn013.
3. Press the DATA/SHIFT Key for at least one second. The following display will appear.
Flashes for
one second.
5 -103
5.7 Absolute Encoders
5