Using the Panel Operator
200V
1. Press the MODE/SET Key to select the auxiliary function mode.
2. Press the Up or Down Cursor Key to select the user constant Fn00D.
3. Press the DATA/SHIFT Key for a minimum of one second, and the display will be as shown
below.
4. Press the MODE/SET Key, and the monitor output for the two channels will be displayed
alternately as shown below.
5. Press the DATA/SHIFT Key for less than one second. The gain constant forthe analogmoni-
tor will be displayed. Pressing the DATA/SHIFT Key again for less than one second will
return to the display shown in the above step 3. or 4.
6. Press the Up or Down Cursor Key to adjust the gain for the analog monitor output.
7. When the gain adjustment has been completed for the two channels, press the DATA/SHIFT
Key for a minimum of one second to return to the auxiliary function mode display.
This completes the manual gain adjustment of the analog monitor output.