3.2.1.2
Removing a Board
The following steps cover the mechanical aspects of removing boards from a ZT 5085 chassis.
1. Determine if your board/slot combination supports hot swap. If the combination does not
support hot swap, disable chassis power prior to proceeding.
2. If hot swap is supported and the system is powered, disengage the ejector to notify software
that the board is about to be removed, and wait for the hot swap LED to light.
3. Unscrew any retention screws that fasten the board to the enclosure. If the board occupies
multiple slots, unscrew the retention screws in each occupied slot.
4. Open the ejectors fully, rotating the handles outward until the board disengages from the
midplane (refer to
5. Disconnect connections at the faceplate.
6. Slide the board evenly out of the enclosure.
7. Install a replacement board or an air management board to maintain the enclosure's shielding
and cooling performance.
8. Enable chassis power if it was disabled in step 1.
Technical Product Specification
Figure 16 on page
33).
Field Replaceable Units
37